Date: Wed, 25 Nov 1998 09:42:42 -0800 From: Russell E Owen Subject: Re: 3.5-meter night log 981124 > ...All was running smoothly and we figured out the "Horizon" > rotation questions with help of Russ Owen and Gordon Richards. The guide > star walks across the frame, and this shows up as guider offsets normal > in X but huge in Y. These are taken into account and will not affect the > guiding, though it may look strange on the guider display. I also found > that due to this walking the guide star must be fairly bright, to allow > short integrations, or else the star is too smeared out to be centroided > properly. Excellent news! I'm glad it's working after all. One brief comment that is probably obvious: guiding during anything except object rotation will introduce a systematic error of roughly half the distance the star "walks" across the CCD -- hence a bigger error for longer integrations or at points in the sky where the field is rotating more quickly. This is just due to the affect of averaging -- the centroid is correct for the instant of time halfway through the integration, but the guiding correction based on that centroid is applied after the integration is finished. -- Russell