APACHE POINT OBSERVATORY SDSS 2.5M OBSERVING LOG Wednesday February 25, 2026 (SJD 61097) ---- Observing Team ---- Dmitry Bizyaev ---- Observing Plan ---- Wed 25 Feb 2026 61097 0.70 01:50 02:05 12:26 05:25 15:48 --- bright until 10:12 ( 8.4 h, w/ 0.2 h for 12 deg design), then dark ( 2.2 h) ---- Observing Summary ---- Started with cloudy sky at the evening twilight, and GFAs didn't converge on the first. low altitude field. Relaced the field with a higher one, hence started observing with a short delay. The rest of the night the sky transparency was not ideal due to waves of clouds, but all designs from the night program were successfully observed. Notes ===== - dust collected: 4.5K - Tonight's attempts to connect to sdss5-hub services, as well as to the machine itself, result to 20-30 sec delays. After that the connection behaves well without delays. Reported to Shane, and he said he has encounered with it before and will try to fix it at the level of VM management software. - the "Trajectory failed with error: Something went wrong" failure happened 2 times tonight. - 07:37Z The high-Dec field guiding test performed with the field-design 102145-770000-24974. Dec = 87:47:29. As expected, cherno reported a large ROT error that didn't apply automatically. It was applied manually via the "tcc offset guide" command. Not that in this case the corrcton is applied with reported sign, not with the opposite. Afte the correction the field was acquired, but very slowly - it took 21 GFA iterations. During them I changed the GFA exposure time when the r.m.s. stopped converging. The best exposure time was 10 sec. Science exposures were obtained. Apparently, the large correction shouldn't be applied back at the end of the field (as it is written in the test instruction) since it screws up the next fields acquisition, see log. ---- Automatic Summary ---- Time Field-Design-Conf DesignType BOSS/APOGEE Seeing Overhead Complete? Comment 01:46:30 103462-771813-24955 bright_time 1x730/1xAB 1.8" 0:00 DONE partly cloudy 02:05:15 103421-771723-24956 bright_time 1x730/1xAB 1.6" 6:01 DONE .. 02:23:27 103450-771787-24957 bright_time 1x730/1xAB 1.4" 5:58 DONE 02:41:32 103467-771830-24958 bright_time 1x730/1xAB 1.6" 5:34 DONE 02:59:22 103428-771740-24959 bright_time 1x730/1xAB 1.6" 5:52 DONE 03:17:24 103465-771823-24960 bright_time 1x730/1xAB 1.4" 5:49 DONE 03:35:24 103429-771741-24961 bright_time 1x730/1xAB 1.4" 5:50 DONE 03:53:25 103400-771682-24962 bright_time 1x730/1xAB 1.5" 7:14 DONE 04:12:47 103401-771684-24963 bright_time 1x730/1xAB 1.4" 6:03 DONE 04:30:59 103395-771671-24964 bright_time 1x730/1xAB 1.5" 6:03 DONE 04:49:18 104359-772664-24965 bright_time 1x730/1xAB 1.6" 5:39 DONE 05:07:08 104356-772652-24966 bright_time 1x730/1xAB 1.5" 6:06 DONE 05:25:26 104375-772691-24967 bright_time_no_apogee_skies 1x730/1xAB 1.8" 6:26 DONE 05:44:03 101289-768725-24968 bright_time_no_apogee_skies 1x730/1xAB 1.9" 6:09 DONE 06:02:23 102988-770833-24969 bright_time_no_apogee_skies 1x730/1xAB 1.9" 7:03 DONE 06:21:40 102998-770845-24970 bright_time_no_apogee_skies 1x730/1xAB 1.9" 7:22 DONE 06:41:45 102957-770802-24971 bright_time_no_apogee_skies 1x730/1xAB 1.9" 6:48 DONE 07:00:07 101242-768702-24972 bright_time_no_apogee_skies 1x730/1xAB 1.6" 6:22 DONE 07:18:40 100813-768373-24973 bright_time_no_apogee_skies 1x730/1xAB 1.9" 6:18 DONE 07:37:10 102145-770000-24974 bright_time_no_apogee_skies 2x730/2xAB 2.0" 21:08 DONE Polar guiding test 08:25:10 101352-753564-24975 bright_time_no_apogee_skies 1x730/1xAB 2.4" 10:34 DONE Flat, Hartmann 08:49:07 101392-753581-24976 bright_time_no_apogee_skies 1x730/1xAB 2.6" 8:47 DONE 09:08:17 101377-753574-24977 bright_time_no_apogee_skies 1x730/1xAB 2.2" 5:54 DONE 09:26:25 101385-753577-24978 bright_time_no_apogee_skies 1x730/1xAB 1.9" 8:00 DONE 09:46:36 100111-751887-24979 bright_time_no_apogee_skies 1x730/1xAB 2.1" 8:04 DONE 10:08:36 103334-755362-24980 dark_monit_no_apogee_skies 1x900/1xAB 1.5" 10:37 done 10:32:30 103334-755363-24981 dark_monit_no_apogee_skies 1x900/1xAB 1.9" 5:01 done 10:52:31 103334-755364-24982 dark_monit_no_apogee_skies 1x900/1xAB 1.6" 5:24 done 11:12:56 103334-755365-24983 dark_monit_no_apogee_skies 1x900/1xAB 1.7" 5:22 DONE epoch 11:33:19 102400-754391-24984 dark_faint_no_apogee_skies 1x900/1xAB 1.4" 6:59 done 11:55:20 102400-754392-24985 dark_faint_no_apogee_skies 1x900/1xAB 1.3" 4:47 done 12:15:10 102400-754393-24986 dark_faint_no_apogee_skies 1x900/1xAB 1.2" 5:26 DONE epoch 12:35:34 100550-752796-24987 bright_time 1x730/1xAB 2.4" 6:52 96.6% complete ---- Observing Log ---- Afternoon ========= All systems checked and no problems found. The BOSS collimation looks OK, nt adjusted: 23:54:47 Hartmann collimate output sp1: offset: r= -1979 (Out of focus); b= 2.8 (In Focus) sp1: pred. move: spAverageMove= -1439 sp1: pred. resid: r= -540, b= -1.7, txt= OK, spTemp = 5.8 cwPositions = 33 32 33 32; MCP instr = 10 (mounted); ---------- motorPosition sp1: -2204, -2192, -2160; ---------- Median spectrographs temperatures: Tsp1= 5.8 Outside air temperature= 0.0; ---------- Boss CCD Temp : sp1r0= -126.6 (-126.6); sp1b2= -101.2 (-100.0); sp1LN2: 10.0; ---------- Apogee: vacuum = 4.61e-07 ( < 1.1e-06 ) ln2Level = 93.51 ( > 85 ) ---------- Weather: Humidity = 34.2 % AirTemp = 11.5 C, DpTemp = -3.7 C diff= 15.2 C wind25m = 15.8 mph, direction = 262.4 deg ---------- semOwner = TCC:0:0 stuiVer=(1.7.19 2023-01-12), pid = 18455 memory = 522 MB ---------- Jaeger disabled robots: 572, 647, 973, 986, 994, 1126 There are 6 disabled robots 23:02:24 apogee exposure file= apRaw-55350001 3 B ArcLamp 23:02:49 boss exposure 0 sec file=0396879 bias 23:04:25 boss exposure 20 sec file=0396880 dark ======================================================= =====>>>>> 23:05:05 Config Loaded: -999--999-24953 ======================================================= 23:05:43 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0001.fits 23:05:42 fvc_perc_90= 50.9 fvc_percent_reached= 1.8 fvc_rms= 36.22 23:05:56 apogee exposure file= apRaw-55350002 60 B Dark 23:16:48 apogee exposure file= apRaw-55350003 10 B QuartzFlat 23:18:40 apogee exposure file= apRaw-55350004 12 B ArcLamp 23:20:52 apogee exposure file= apRaw-55350005 40 B ArcLamp 23:28:10 apogee exposure file= apRaw-55350006 12 A ArcLamp 23:30:22 apogee exposure file= apRaw-55350007 40 A ArcLamp 23:37:48 apogee exposure file= apRaw-55350008 60 A Dark 23:48:39 apogee exposure file= apRaw-55350009 30 A ArcLamp 23:54:02 apogee exposure file= apRaw-55350010 30 B ArcLamp 23:52:44 boss exposure 4 sec file=0396881 arc 23:53:25 boss exposure 4 sec file=0396882 arc 23:54:42 Hartmann: offset r= -1979 (Out of focus) b = 2.8 (In Focus) pred_move = -1439 pred_resid r= -540 b= -1.7 cmnt=OK 23:55:23 boss exposure 4 sec file=0396883 arc 23:57:50 boss exposure 25 sec file=0396884 flat 00:00Z ventilation started. The sky is cloudy. ===== Night ===== 01:03Z enclosure open. The sky is partly cloudy. 01:07:14 apogee exposure file= apRaw-55350011 5 B DomeFlat - DO NOT USE, too bright 01:16:55 apogee exposure file= apRaw-55350012 5 B DomeFlat 01:18:11 apogee exposure file= apRaw-55350013 5 B DomeFlat 01:19:26 apogee exposure file= apRaw-55350014 5 B DomeFlat MJD DomeFlat MTPs:1 2 3 4 5 6 7 8 9 10 AZ ALT ROT 61097 55350011 1.04 1.03 1.03 1.05 1.06 1.02 0.96 1.02 1.02 0.99 121.0 30.0 0.0 61097 55350012 1.03 1.03 1.03 1.03 1.04 1.01 0.96 1.01 1.00 0.96 121.0 30.0 0.0 61097 55350013 1.04 1.02 1.02 1.03 1.04 1.01 0.96 1.00 0.99 0.96 121.0 30.0 0.0 61097 55350014 1.03 1.02 1.01 1.02 1.03 1.01 0.95 1.00 0.99 0.95 121.0 30.0 0.0 01:20:51 boss exposure 25 sec file=0396885 flat 01:22:38 boss exposure 25 sec file=0396886 flat 01:24:25 boss exposure 25 sec file=0396887 flat ======================================================= =====>>>>> 01:26:40 Config Loaded: 100281-752081-24954 ======================================================= 01:29:09 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0002.fits 01:28:59 fvc_perc_90= 61.6 fvc_percent_reached= 2.6 fvc_rms= 40.92 01:29:36 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0003.fits 01:29:35 fvc_perc_90= 9.6 fvc_percent_reached= 63.4 fvc_rms= 15.68 01:29:26 boss exposure 4 sec file=0396888 arc 01:30:06 boss exposure 4 sec file=0396889 arc 01:31:22 Hartmann: offset r= 2638 (Out of focus) b = -6.2 (Out of focus) pred_move = 2315 pred_resid r= 323 b= 1.0 cmnt=OK 01:31:53 boss exposure 4 sec file=0396890 arc Acquisition is very much delayed bacause of thick clouds. The rms. fluctuates but never goes below 1". 1:32:49 hal.hal 127445 cherno i guide_rms=17,10.578,16.132,19.291 01:33:17 hal.hal 127445 cherno i guide_rms=18,6.371,0.666,6.406 01:33:47 hal.hal 127445 cherno i guide_rms=19,1.617,1.469,2.184 01:34:27 hal.hal 127445 cherno i guide_rms=20,0.815,0.799,1.141 01:35:17 hal.hal 127445 cherno i guide_rms=21,3.137,2.054,3.749 01:36:40 APO.dmbiz_2 5 cherno i guide_rms=25,0.653,2.545,2.628 01:37:06 APO.dmbiz_2 5 cherno i guide_rms=26,1.456,2.161,2.605 01:37:29 APO.dmbiz_2 5 cherno i guide_rms=27,1.417,2.044,2.487 01:37:55 APO.dmbiz_2 5 cherno i guide_rms=28,2.59,0.916,2.747 01:38:19 APO.dmbiz_2 5 cherno i guide_rms=29,4.057,2.599,4.818 01:38:42 APO.dmbiz_2 5 cherno i guide_rms=30,0.156,2.251,2.256 01:39:06 APO.dmbiz_2 5 cherno i guide_rms=31,1.082,0.613,1.244 01:39:35 APO.dmbiz_2 5 cherno i guide_rms=32,2.297,0.89,2.464 01:40:03 APO.dmbiz_2 5 cherno i guide_rms=33,2.371,0.168,2.376 01:40:28 APO.dmbiz_2 5 cherno i guide_rms=34,0.086,3.911,3.912 01:41:10 APO.dmbiz_2 5 cherno i guide_rms=36,0.443,2.924,2.957 01:41:40 APO.dmbiz_2 5 cherno i guide_rms=37,10.036,6.77,12.106 01:42:09 APO.dmbiz_2 5 cherno i guide_rms=38,8.869,4.808,10.088 01:42:37 APO.dmbiz_2 5 cherno i guide_rms=39,5.138,6.08,7.96 01:43:10 APO.dmbiz_2 5 cherno i guide_rms=40,0.866,2.151,2.319 01:43:37 APO.dmbiz_2 5 cherno i guide_rms=41,0.313,4.319,4.331 01:44:05 APO.dmbiz_2 5 cherno i guide_rms=42,4.23,4.481,6.162 Decided to change the field to a higher one. ======================================================= =====>>>>> 01:46:30 Config Loaded: 103462-771813-24955 ======================================================= 01:49:11 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0004.fits 01:49:02 fvc_perc_90= 57.9 fvc_percent_reached= 2.8 fvc_rms= 40.66 01:49:38 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0005.fits 01:49:36 fvc_perc_90= 9.5 fvc_percent_reached= 64.3 fvc_rms= 10.57 01:50:28 boss exposure 4 sec file=0396891 arc 01:52:34 apogee exposure file= apRaw-55350015 35 A Object 01:52:51 boss exposure 730 sec file=0396892 science 01:58:50 apogee exposure file= apRaw-55350016 35 B Object ======================================================= =====>>>>> 02:05:15 Config Loaded: 103421-771723-24956 ======================================================= 02:07:55 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0006.fits 02:07:43 fvc_perc_90= 54.5 fvc_percent_reached= 2.7 fvc_rms= 36.62 02:08:21 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0007.fits 02:08:20 fvc_perc_90= 9.5 fvc_percent_reached= 59.0 fvc_rms= 8.86 02:09:10 boss exposure 4 sec file=0396893 arc 02:10:46 apogee exposure file= apRaw-55350017 35 A Object 02:11:03 boss exposure 730 sec file=0396894 science 02:17:02 apogee exposure file= apRaw-55350018 35 B Object ======================================================= =====>>>>> 02:23:27 Config Loaded: 103450-771787-24957 ======================================================= 02:26:02 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0008.fits 02:25:43 fvc_perc_90= 56.9 fvc_percent_reached= 1.8 fvc_rms= 37.43 02:26:29 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0009.fits 02:26:28 fvc_perc_90= 8.9 fvc_percent_reached= 65.6 fvc_rms= 7.44 02:27:18 boss exposure 4 sec file=0396895 arc 02:28:51 apogee exposure file= apRaw-55350019 35 A Object 02:29:10 boss exposure 730 sec file=0396896 science 02:35:07 apogee exposure file= apRaw-55350020 35 B Object ======================================================= =====>>>>> 02:41:32 Config Loaded: 103467-771830-24958 ======================================================= 02:43:57 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0010.fits 02:43:47 fvc_perc_90= 57.5 fvc_percent_reached= 3.9 fvc_rms= 41.57 02:44:23 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0011.fits 02:44:22 fvc_perc_90= 9.5 fvc_percent_reached= 64.5 fvc_rms= 28.65 02:45:14 boss exposure 4 sec file=0396897 arc 02:46:40 apogee exposure file= apRaw-55350021 35 A Object 02:46:56 boss exposure 730 sec file=0396898 science 02:52:56 apogee exposure file= apRaw-55350022 35 B Object ======================================================= =====>>>>> 02:59:22 Config Loaded: 103428-771740-24959 ======================================================= 03:01:45 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0012.fits 03:01:33 fvc_perc_90= 58.7 fvc_percent_reached= 1.4 fvc_rms= 38.96 03:02:11 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0013.fits 03:02:10 fvc_perc_90= 9.3 fvc_percent_reached= 64.6 fvc_rms= 9.16 03:03:01 boss exposure 4 sec file=0396899 arc 03:04:43 apogee exposure file= apRaw-55350023 35 A Object 03:04:59 boss exposure 730 sec file=0396900 science 03:10:59 apogee exposure file= apRaw-55350024 35 B Object ======================================================= =====>>>>> 03:17:24 Config Loaded: 103465-771823-24960 ======================================================= 03:19:45 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0014.fits 03:19:35 fvc_perc_90= 59.2 fvc_percent_reached= 1.8 fvc_rms= 37.69 03:20:16 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0015.fits 03:20:15 fvc_perc_90= 9.2 fvc_percent_reached= 60.6 fvc_rms= 6.75 03:21:10 boss exposure 4 sec file=0396901 arc 03:22:43 apogee exposure file= apRaw-55350025 35 A Object 03:22:59 boss exposure 730 sec file=0396902 science 03:28:59 apogee exposure file= apRaw-55350026 35 B Object ======================================================= =====>>>>> 03:35:24 Config Loaded: 103429-771741-24961 ======================================================= 03:37:55 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0016.fits 03:37:45 fvc_perc_90= 56.8 fvc_percent_reached= 1.6 fvc_rms= 41.0 03:38:21 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0017.fits 03:38:20 fvc_perc_90= 9.5 fvc_percent_reached= 61.5 fvc_rms= 9.34 03:39:10 boss exposure 4 sec file=0396903 arc 03:40:44 apogee exposure file= apRaw-55350027 35 A Object 03:41:00 boss exposure 730 sec file=0396904 science 03:47:00 apogee exposure file= apRaw-55350028 35 A Object ======================================================= =====>>>>> 03:53:25 Config Loaded: 103400-771682-24962 ======================================================= 03:54:45 hal.hal 127702 jaeger f error="Trajectory failed with error: Something went wrong sending the trajectory: At least one SEND_TRAJECTORY_COMMAND timed out" 03:54:45 CmdDone: hal.hal 127702 jaeger configuration execute Nothing done other that clearing axes and restarting the go to field sequence. 03:57:21 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0018.fits 03:57:11 fvc_perc_90= 59.6 fvc_percent_reached= 2.0 fvc_rms= 37.71 03:57:47 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0019.fits 03:57:46 fvc_perc_90= 9.9 fvc_percent_reached= 61.9 fvc_rms= 6.22 03:58:35 boss exposure 4 sec file=0396905 arc 03:59:59 apogee exposure file= apRaw-55350029 35 B Object 04:00:25 boss exposure 730 sec file=0396906 science 04:06:20 apogee exposure file= apRaw-55350030 35 A Object ======================================================= =====>>>>> 04:12:47 Config Loaded: 103401-771684-24963 ======================================================= 04:15:04 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0020.fits 04:14:55 fvc_perc_90= 58.6 fvc_percent_reached= 2.4 fvc_rms= 38.27 04:15:31 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0021.fits 04:15:30 fvc_perc_90= 9.5 fvc_percent_reached= 61.9 fvc_rms= 6.51 04:16:26 boss exposure 4 sec file=0396907 arc 04:18:15 apogee exposure file= apRaw-55350031 35 A Object 04:18:40 boss exposure 730 sec file=0396908 science 04:24:31 apogee exposure file= apRaw-55350032 35 B Object ======================================================= =====>>>>> 04:30:59 Config Loaded: 103395-771671-24964 ======================================================= 04:33:20 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0022.fits 04:33:10 fvc_perc_90= 57.7 fvc_percent_reached= 1.8 fvc_rms= 42.59 04:33:46 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0023.fits 04:33:45 fvc_perc_90= 8.8 fvc_percent_reached= 65.0 fvc_rms= 18.66 04:34:36 boss exposure 4 sec file=0396909 arc 04:36:37 apogee exposure file= apRaw-55350033 35 A Object 04:36:52 boss exposure 730 sec file=0396910 science 04:42:53 apogee exposure file= apRaw-55350034 35 B Object ======================================================= =====>>>>> 04:49:18 Config Loaded: 104359-772664-24965 ======================================================= 04:51:39 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0024.fits 04:51:29 fvc_perc_90= 59.1 fvc_percent_reached= 4.3 fvc_rms= 36.51 04:52:05 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0025.fits 04:52:04 fvc_perc_90= 8.9 fvc_percent_reached= 63.3 fvc_rms= 6.44 04:52:53 boss exposure 4 sec file=0396911 arc 04:54:27 apogee exposure file= apRaw-55350035 35 A Object 04:54:43 boss exposure 730 sec file=0396912 science 05:00:43 apogee exposure file= apRaw-55350036 35 B Object ======================================================= =====>>>>> 05:07:08 Config Loaded: 104356-772652-24966 ======================================================= 05:09:34 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0026.fits 05:09:24 fvc_perc_90= 60.4 fvc_percent_reached= 2.7 fvc_rms= 41.94 05:10:00 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0027.fits 05:09:59 fvc_perc_90= 9.0 fvc_percent_reached= 62.4 fvc_rms= 12.56 05:10:49 boss exposure 4 sec file=0396913 arc 05:12:44 apogee exposure file= apRaw-55350037 35 A Object 05:13:00 boss exposure 730 sec file=0396914 science 05:19:01 apogee exposure file= apRaw-55350038 35 B Object ======================================================= =====>>>>> 05:25:26 Config Loaded: 104375-772691-24967 ======================================================= 05:28:04 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0028.fits 05:27:54 fvc_perc_90= 58.5 fvc_percent_reached= 0.8 fvc_rms= 38.59 05:28:30 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0029.fits 05:28:29 fvc_perc_90= 9.3 fvc_percent_reached= 63.0 fvc_rms= 7.0 05:29:19 boss exposure 4 sec file=0396915 arc 05:31:21 apogee exposure file= apRaw-55350039 35 A Object 05:31:37 boss exposure 730 sec file=0396916 science 05:37:38 apogee exposure file= apRaw-55350040 35 B Object ======================================================= =====>>>>> 05:44:03 Config Loaded: 101289-768725-24968 ======================================================= 05:46:27 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0030.fits 05:46:13 fvc_perc_90= 58.9 fvc_percent_reached= 1.2 fvc_rms= 38.14 05:46:53 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0031.fits 05:46:52 fvc_perc_90= 9.3 fvc_percent_reached= 63.0 fvc_rms= 7.95 05:47:41 boss exposure 4 sec file=0396917 arc 05:49:42 apogee exposure file= apRaw-55350041 35 A Object 05:49:57 boss exposure 730 sec file=0396918 science 05:55:58 apogee exposure file= apRaw-55350042 35 B Object ======================================================= =====>>>>> 06:02:23 Config Loaded: 102988-770833-24969 ======================================================= 06:05:02 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0032.fits 06:04:52 fvc_perc_90= 55.0 fvc_percent_reached= 3.2 fvc_rms= 35.69 06:05:28 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0033.fits 06:05:27 fvc_perc_90= 9.3 fvc_percent_reached= 61.3 fvc_rms= 7.98 06:06:30 boss exposure 4 sec file=0396919 arc 06:08:56 apogee exposure file= apRaw-55350043 35 A Object 06:09:11 boss exposure 730 sec file=0396920 science 06:15:12 apogee exposure file= apRaw-55350044 35 B Object ======================================================= =====>>>>> 06:21:40 Config Loaded: 102998-770845-24970 ======================================================= 06:22:45 hal.hal 127991 jaeger f error="Trajectory failed with error: Something went wrong sending the trajectory: At least one SEND_TRAJECTORY_COMMAND timed out" 06:22:45 CmdDone: hal.hal 127991 jaeger configuration execute Nothing done other that clearing axes and restarting the go to field sequence. 06:24:54 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0034.fits 06:24:45 fvc_perc_90= 55.9 fvc_percent_reached= 2.8 fvc_rms= 36.79 06:25:21 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0035.fits 06:25:20 fvc_perc_90= 9.5 fvc_percent_reached= 60.3 fvc_rms= 8.36 06:26:11 boss exposure 4 sec file=0396921 arc 06:28:20 apogee exposure file= apRaw-55350045 35 B Object 06:28:44 boss exposure 730 sec file=0396922 science 06:34:41 apogee exposure file= apRaw-55350046 35 A Object ======================================================= =====>>>>> 06:41:45 Config Loaded: 102957-770802-24971 ======================================================= 06:44:09 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0036.fits 06:44:00 fvc_perc_90= 51.3 fvc_percent_reached= 2.0 fvc_rms= 38.65 06:44:36 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0037.fits 06:44:35 fvc_perc_90= 9.7 fvc_percent_reached= 58.6 fvc_rms= 7.63 06:45:29 boss exposure 4 sec file=0396923 arc 06:47:19 apogee exposure file= apRaw-55350047 35 A Object 06:47:43 boss exposure 730 sec file=0396924 science 06:53:35 apogee exposure file= apRaw-55350048 35 B Object ======================================================= =====>>>>> 07:00:07 Config Loaded: 101242-768702-24972 ======================================================= 07:02:44 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0038.fits 07:02:34 fvc_perc_90= 57.4 fvc_percent_reached= 3.4 fvc_rms= 38.42 07:03:10 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0039.fits 07:03:09 fvc_perc_90= 8.9 fvc_percent_reached= 64.7 fvc_rms= 8.87 07:03:59 boss exposure 4 sec file=0396925 arc 07:05:59 apogee exposure file= apRaw-55350049 35 A Object 07:06:15 boss exposure 730 sec file=0396926 science 07:12:15 apogee exposure file= apRaw-55350050 35 B Object ======================================================= =====>>>>> 07:18:40 Config Loaded: 100813-768373-24973 ======================================================= 07:21:15 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0040.fits 07:21:06 fvc_perc_90= 54.4 fvc_percent_reached= 3.2 fvc_rms= 36.71 07:21:42 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0041.fits 07:21:41 fvc_perc_90= 8.4 fvc_percent_reached= 66.0 fvc_rms= 5.51 07:22:30 boss exposure 4 sec file=0396927 arc 07:24:30 apogee exposure file= apRaw-55350051 35 A Object 07:24:48 boss exposure 730 sec file=0396928 science 07:30:45 apogee exposure file= apRaw-55350052 35 B Object ======================================================= =====>>>>> 07:37:10 Config Loaded: 102145-770000-24974 ======================================================= ************************************************ THIS IS A HIGH DECLINATION FIELD, Dec = 87:47:21 ************************************************ Conditions: light clouds, seeing ~ 2". The Moon is up but away from the field. HA ~ -04:30 - -04:00 07:39:26 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0042.fits 07:39:16 fvc_perc_90= 62.2 fvc_percent_reached= 1.8 fvc_rms= 42.33 07:39:53 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0043.fits 07:39:51 fvc_perc_90= 9.6 fvc_percent_reached= 61.3 fvc_rms= 12.36 07:40:45 boss exposure 4 sec file=0396929 arc Acquisition was failed, but not because of a large rotator offset. The guiders didn't find a decent solution: 07:41:42 hal.hal 128151 cherno i guide_rms=501,189.197,311.11,364.122 Texp = 5 sec: 07:42:50 APO.dmbiz_2 18 cherno i guide_rms=503,187.621,294.857,349.488 Texp = 3 sec: 07:44:10 APO.dmbiz_2 19 cherno f error="Guider failed: Rotator correction too large: 8010.1." 07:44:10 CmdDone: APO.dmbiz_2 19 cherno guide -t 3 07:45:51 CmdDone: APO.dmbiz 63 tcc offset guide /computed 0.0,0.0,-2.225 07:46:28 APO.dmbiz_2 20 cherno f error="Guider failed: Rotator correction too large: 12811.7." 07:46:28 CmdDone: APO.dmbiz_2 20 cherno guide -t 5 Apparently, the sign was wrong. Applied 0.0,0.0,2.225 twice The field acquisition took a long time, and I varied the guider exposure time (from 5 sec at the beginning to 9 to 15 and then back to 10 sec) in response to the r.m.s. change. The optimal exposure time turned out to be 10 sec. 07:47:38 APO.dmbiz_2 21 cherno i guide_rms=506,99.704,102.619,143.079 07:48:07 APO.dmbiz_2 21 cherno i guide_rms=507,40.211,45.676,60.854 07:48:35 APO.dmbiz_2 21 cherno i guide_rms=508,17.578,20.93,27.332 07:49:01 APO.dmbiz_2 21 cherno i guide_rms=509,9.717,12.626,15.932 07:49:27 APO.dmbiz_2 21 cherno i guide_rms=510,6.907,10.01,12.161 07:49:52 APO.dmbiz_2 21 cherno i guide_rms=511,6.359,9.129,11.126 07:50:17 APO.dmbiz_2 21 cherno i guide_rms=512,5.812,8.823,10.565 07:50:48 APO.dmbiz_2 21 cherno i guide_rms=513,7.178,12.704,14.592 07:51:13 APO.dmbiz_2 21 cherno i guide_rms=514,7.471,12.338,14.424 07:51:38 APO.dmbiz_2 21 cherno i guide_rms=515,7.863,12.258,14.563 07:52:05 APO.dmbiz_2 21 cherno i guide_rms=516,8.029,12.617,14.955 07:52:37 APO.dmbiz_2 21 cherno i guide_rms=517,4.635,6.395,7.898 07:53:03 APO.dmbiz_2 21 cherno i guide_rms=518,4.127,5.964,7.253 07:53:30 APO.dmbiz_2 21 cherno i guide_rms=519,4.022,6.206,7.396 07:54:04 APO.dmbiz_2 21 cherno i guide_rms=520,1.883,2.005,2.751 07:54:32 APO.dmbiz_2 21 cherno i guide_rms=521,1.107,1.578,1.928 07:55:01 APO.dmbiz_2 21 cherno i guide_rms=522,0.653,1.621,1.748 07:55:34 APO.dmbiz_2 21 cherno i guide_rms=523,1.71,2.322,2.884 07:56:11 APO.dmbiz_2 21 cherno i guide_rms=524,1.258,1.9,2.279 07:56:46 APO.dmbiz_2 21 cherno i guide_rms=525,0.797,0.901,1.203 07:57:20 APO.dmbiz_2 21 cherno i guide_rms=526,0.314,0.684,0.753 07:57:52 APO.dmbiz_2 21 cherno i guide_rms=527,0.214,0.285,0.356 07:57:40 apogee exposure file= apRaw-55350053 35 B Object 07:58:04 boss exposure 730 sec file=0396930 science 08:04:01 apogee exposure file= apRaw-55350054 35 A Object 08:11:48 apogee exposure file= apRaw-55350055 35 A Object 08:12:13 boss exposure 730 sec file=0396931 science 08:18:05 apogee exposure file= apRaw-55350056 35 B Object ======================================================= =====>>>>> 08:25:10 Config Loaded: 101352-753564-24975 ======================================================= 08:28:57 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0044.fits 08:28:45 fvc_perc_90= 58.5 fvc_percent_reached= 3.3 fvc_rms= 39.47 08:29:24 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0045.fits 08:29:23 fvc_perc_90= 8.7 fvc_percent_reached= 67.8 fvc_rms= 25.72 08:30:12 boss exposure 4 sec file=0396932 arc The first 3 GFA iteratins were skipped because Astrometry.net was unable to find a solution. This happened, probably, because I applied the large reverse correction back in the previous, polar field. Once a star was identified in the current field, it applied a large correction (~4000") and acquired the field. 08:34:33 apogee exposure file= apRaw-55350057 35 B Object 08:34:56 boss exposure 730 sec file=0396933 science 08:40:53 apogee exposure file= apRaw-55350058 35 A Object 08:48:34 boss exposure 25 sec file=0396934 flat ======================================================= =====>>>>> 08:49:07 Config Loaded: 101392-753581-24976 ======================================================= 08:51:20 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0046.fits 08:51:10 fvc_perc_90= 61.0 fvc_percent_reached= 1.0 fvc_rms= 39.9 08:51:51 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0047.fits 08:51:50 fvc_perc_90= 10.1 fvc_percent_reached= 59.1 fvc_rms= 8.24 08:51:41 boss exposure 4 sec file=0396935 arc 08:52:21 boss exposure 4 sec file=0396936 arc 08:53:37 Hartmann: offset r= -989 (In Focus) b = 4.8 (Out of focus) pred_move = -1265 pred_resid r= 276 b= 0.9 cmnt=OK 08:54:06 boss exposure 4 sec file=0396937 arc 08:55:35 apogee exposure file= apRaw-55350059 35 A Object 08:55:55 boss exposure 730 sec file=0396938 science 09:01:51 apogee exposure file= apRaw-55350060 35 B Object ======================================================= =====>>>>> 09:08:17 Config Loaded: 101377-753574-24977 ======================================================= 09:11:00 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0048.fits 09:10:50 fvc_perc_90= 57.3 fvc_percent_reached= 2.2 fvc_rms= 38.94 09:11:26 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0049.fits 09:11:25 fvc_perc_90= 9.1 fvc_percent_reached= 60.2 fvc_rms= 7.68 09:12:17 boss exposure 4 sec file=0396939 arc 09:13:44 apogee exposure file= apRaw-55350061 35 A Object 09:13:59 boss exposure 730 sec file=0396940 science 09:20:00 apogee exposure file= apRaw-55350062 35 B Object ======================================================= =====>>>>> 09:26:25 Config Loaded: 101385-753577-24978 ======================================================= 09:30:16 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0050.fits 09:30:06 fvc_perc_90= 57.4 fvc_percent_reached= 1.6 fvc_rms= 37.7 09:30:42 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0051.fits 09:30:41 fvc_perc_90= 10.0 fvc_percent_reached= 60.1 fvc_rms= 60.2 09:31:33 boss exposure 4 sec file=0396941 arc 09:33:54 apogee exposure file= apRaw-55350063 35 A Object 09:34:12 boss exposure 730 sec file=0396942 science 09:40:10 apogee exposure file= apRaw-55350064 35 B Object ======================================================= =====>>>>> 09:46:36 Config Loaded: 100111-751887-24979 ======================================================= 09:50:30 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0052.fits 09:50:20 fvc_perc_90= 56.5 fvc_percent_reached= 2.0 fvc_rms= 39.15 09:50:56 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0053.fits 09:50:55 fvc_perc_90= 8.3 fvc_percent_reached= 66.9 fvc_rms= 10.8 09:51:45 boss exposure 4 sec file=0396943 arc 09:54:07 apogee exposure file= apRaw-55350065 35 A Object 09:54:27 boss exposure 730 sec file=0396944 science 10:00:23 apogee exposure file= apRaw-55350066 35 B Object ======================================================= =====>>>>> 10:08:36 Config Loaded: 103334-755362-24980 ======================================================= 10:11:01 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0054.fits 10:10:51 fvc_perc_90= 58.5 fvc_percent_reached= 2.8 fvc_rms= 38.55 10:11:27 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0055.fits 10:11:26 fvc_perc_90= 9.3 fvc_percent_reached= 60.0 fvc_rms= 8.27 10:12:02 boss exposure 25 sec file=0396945 flat 10:14:37 boss exposure 4 sec file=0396946 arc 10:16:59 apogee exposure file= apRaw-55350067 43 B Object 10:17:14 boss exposure 900 sec file=0396947 science 10:24:39 apogee exposure file= apRaw-55350068 43 B Object ======================================================= =====>>>>> 10:32:30 Config Loaded: 103334-755363-24981 ======================================================= 10:34:57 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0056.fits 10:34:45 fvc_perc_90= 61.8 fvc_percent_reached= 3.2 fvc_rms= 40.19 10:35:24 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0057.fits 10:35:23 fvc_perc_90= 9.5 fvc_percent_reached= 63.2 fvc_rms= 7.57 10:37:00 apogee exposure file= apRaw-55350069 43 B Object 10:37:15 boss exposure 900 sec file=0396948 science 10:44:41 apogee exposure file= apRaw-55350070 43 B Object ======================================================= =====>>>>> 10:52:31 Config Loaded: 103334-755364-24982 ======================================================= 10:54:53 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0058.fits 10:54:43 fvc_perc_90= 63.3 fvc_percent_reached= 1.2 fvc_rms= 40.99 10:55:19 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0059.fits 10:55:18 fvc_perc_90= 8.9 fvc_percent_reached= 64.2 fvc_rms= 7.81 10:57:25 apogee exposure file= apRaw-55350071 43 A Object 10:57:41 boss exposure 900 sec file=0396949 science 11:05:06 apogee exposure file= apRaw-55350072 43 B Object ======================================================= =====>>>>> 11:12:56 Config Loaded: 103334-755365-24983 ======================================================= 11:15:18 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0060.fits 11:15:08 fvc_perc_90= 64.0 fvc_percent_reached= 1.6 fvc_rms= 40.71 11:15:44 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0061.fits 11:15:43 fvc_perc_90= 9.4 fvc_percent_reached= 62.1 fvc_rms= 7.54 11:17:48 apogee exposure file= apRaw-55350073 43 A Object 11:18:03 boss exposure 900 sec file=0396950 science 11:25:28 apogee exposure file= apRaw-55350074 43 B Object ======================================================= =====>>>>> 11:33:19 Config Loaded: 102400-754391-24984 ======================================================= 11:35:38 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0062.fits 11:35:29 fvc_perc_90= 55.9 fvc_percent_reached= 3.2 fvc_rms= 39.42 11:36:04 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0063.fits 11:36:03 fvc_perc_90= 10.3 fvc_percent_reached= 59.3 fvc_rms= 8.75 11:37:00 boss exposure 4 sec file=0396951 arc 11:39:48 apogee exposure file= apRaw-55350075 43 A Object 11:40:05 boss exposure 900 sec file=0396952 science 11:47:29 apogee exposure file= apRaw-55350076 43 B Object ======================================================= =====>>>>> 11:55:20 Config Loaded: 102400-754392-24985 ======================================================= 11:57:40 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0064.fits 11:57:31 fvc_perc_90= 58.0 fvc_percent_reached= 2.0 fvc_rms= 38.73 11:58:07 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0065.fits 11:58:06 fvc_perc_90= 9.6 fvc_percent_reached= 59.5 fvc_rms= 6.68 11:59:36 apogee exposure file= apRaw-55350077 43 A Object 11:59:52 boss exposure 900 sec file=0396953 science 12:07:17 apogee exposure file= apRaw-55350078 43 B Object ======================================================= =====>>>>> 12:15:10 Config Loaded: 102400-754393-24986 ======================================================= 12:17:31 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0066.fits 12:17:22 fvc_perc_90= 62.7 fvc_percent_reached= 2.6 fvc_rms= 40.15 12:17:58 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0067.fits 12:17:57 fvc_perc_90= 10.0 fvc_percent_reached= 56.5 fvc_rms= 13.68 12:20:03 apogee exposure file= apRaw-55350079 43 A Object 12:20:18 boss exposure 900 sec file=0396954 science 12:27:44 apogee exposure file= apRaw-55350080 43 B Object ======================================================= =====>>>>> 12:35:34 Config Loaded: 100550-752796-24987 ======================================================= 12:38:00 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0068.fits 12:37:50 fvc_perc_90= 57.2 fvc_percent_reached= 3.0 fvc_rms= 40.88 12:38:26 FVC exposure image /data/fcam/61097/proc-fimg-fvc1n-0069.fits 12:38:25 fvc_perc_90= 9.5 fvc_percent_reached= 58.6 fvc_rms= 7.26 12:39:25 boss exposure 4 sec file=0396955 arc 12:41:54 apogee exposure file= apRaw-55350081 35 A Object 12:42:12 boss exposure 730 sec file=0396956 science 12:48:10 apogee exposure file= apRaw-55350082 35 B Object 12:54:47 apogee exposure file= apRaw-55350083 5 B DomeFlat 12:56:02 apogee exposure file= apRaw-55350084 5 B DomeFlat 12:57:17 apogee exposure file= apRaw-55350085 5 B DomeFlat MJD DomeFlat MTPs:1 2 3 4 5 6 7 8 9 10 AZ ALT ROT 61097 55350083 0.99 1.02 1.01 1.01 1.03 1.03 0.97 1.01 1.00 0.97 48.2 43.5 245.5 ... 12:58:43 boss exposure 25 sec file=0396957 flat 13:03:22 boss exposure 4 sec file=0396959 arc 13:14Z enclosure closed. Calibrations started. [ (55350001, 3, 3, '/data/apogee/raw/61097/apRaw-55350001-001.fits', 'ARCLAMP', 'None', '', '24952', '755233', '103235', 32.041, '2026-02-25T23:02:24.878', 'Podium', 'Closed', 'Closed', 61097, 'APO', 13.499)] problem with exposure: 55350001 Using nfowler=1 for DOMEFLAT Using nfowler=1 for DOMEFLAT Using nfowler=1 for DOMEFLAT Using nfowler=1 for DOMEFLAT Using nfowler=1 for DOMEFLAT Using nfowler=1 for DOMEFLAT Using nfowler=1 for DOMEFLAT num field design config exptype dithpix nread relflux okay dx dy sigx sigy fpi1 fpi2 -------- ------ ------ ------ ------------ ------- ----- ------- ----- ------- ------- ------ ------ ---- ---- 55350001 103235 755233 24952 ARCLAMP-None 13.5 3 0 False 0.00 0.00 0.00 0.00 0 0 55350002 -999 -999 24953 DARK 13.5 60 -22 True -- -- -- -- -- -- 55350003 -999 -999 24953 QUARTZFLAT 13.5 10 108 True -- 0.63 -- 0.85 -- -- 55350004 -999 -999 24953 ARCLAMP-THAR 13.5 12 89 True 23.55 1.29 1.06 0.91 -- -- 55350005 -999 -999 24953 ARCLAMP-UNE 13.5 40 4 True -10.54 -5.03 1.38 0.93 -- -- 55350006 -999 -999 24953 ARCLAMP-THAR 13.0 12 94 True 23.05 1.29 1.07 0.91 -- -- 55350007 -999 -999 24953 ARCLAMP-UNE 13.0 40 2 True -11.46 -5.10 0.41 0.89 -- -- 55350008 -999 -999 24953 DARK 13.0 60 -2 True -- -- -- -- -- -- 55350009 -999 -999 24953 FPI 13.0 30 234 True 10.05 -5.20 1.11 0.90 -- -- 55350010 -999 -999 24953 FPI 13.5 30 232 True -14.16 -5.18 1.12 0.90 -- -- 55350011 -999 -999 24953 DOMEFLAT 13.5 5 179 True -- 0.64 -- 0.86 -- -- 55350012 -999 -999 24953 DOMEFLAT 13.5 5 111 True -- 0.64 -- 0.85 -- -- 55350013 -999 -999 24953 DOMEFLAT 13.5 5 107 True -- 0.65 -- 0.82 -- -- 55350014 -999 -999 24953 DOMEFLAT 13.5 5 109 True -- 0.64 -- 0.85 -- -- 55350015 103462 771813 24955 OBJECT 13.0 35 100 True 23.18 0.59 1.68 0.90 99 162 55350016 103462 771813 24955 OBJECT 13.5 35 3 True -14.49 0.65 0.30 0.84 98 162 55350017 103421 771723 24956 OBJECT 13.0 35 8 True -14.50 0.65 0.30 0.87 104 168 55350018 103421 771723 24956 OBJECT 13.5 35 8 True -14.49 0.65 0.30 0.87 100 166 55350019 103450 771787 24957 OBJECT 13.0 35 90 True 23.17 0.61 1.68 0.89 100 161 55350020 103450 771787 24957 OBJECT 13.5 35 4 True -14.49 0.65 0.30 0.85 96 166 55350021 103467 771830 24958 OBJECT 13.0 35 62 True 23.28 -6.13 1.79 0.92 101 165 55350022 103467 771830 24958 OBJECT 13.5 35 0 True 0.34 -5.84 0.30 0.96 98 166 55350023 103428 771740 24959 OBJECT 13.0 35 69 True 23.00 0.44 1.76 0.96 100 169 55350024 103428 771740 24959 OBJECT 13.5 35 68 True 23.47 0.40 1.74 0.92 101 169 55350025 103465 771823 24960 OBJECT 13.0 35 1 True -16.95 2.22 0.34 0.60 95 160 55350026 103465 771823 24960 OBJECT 13.5 35 62 True 23.46 0.48 1.71 0.88 95 163 55350027 103429 771741 24961 OBJECT 13.0 35 54 True 23.26 -6.08 1.77 0.91 100 170 55350028 103429 771741 24961 OBJECT 13.5 35 51 True 23.72 -6.01 1.71 0.86 98 169 55350029 103400 771682 24962 OBJECT 13.5 35 11 True 7.49 -5.97 0.30 0.90 102 169 55350030 103400 771682 24962 OBJECT 13.0 35 11 True -8.51 -5.96 0.30 0.89 102 168 55350031 103401 771684 24963 OBJECT 13.0 35 45 True 23.26 -6.12 1.78 0.90 103 168 55350032 103401 771684 24963 OBJECT 13.5 35 43 True 23.73 -6.04 1.70 0.89 96 167 55350033 103395 771671 24964 OBJECT 13.0 35 56 True 23.16 0.55 1.70 0.91 100 163 55350034 103395 771671 24964 OBJECT 13.5 35 57 True 23.65 0.58 1.75 0.87 100 168 55350035 104359 772664 24965 OBJECT 13.0 35 16 True -8.49 0.67 0.30 0.86 102 170 55350036 104359 772664 24965 OBJECT 13.5 35 17 True -7.51 0.67 0.30 0.86 98 171 55350037 104356 772652 24966 OBJECT 13.0 35 9 True -13.50 -5.95 0.30 0.87 102 170 55350038 104356 772652 24966 OBJECT 13.5 35 8 True -12.50 -5.96 0.30 0.87 99 170 55350039 104375 772691 24967 OBJECT 13.0 35 47 True 23.00 0.43 1.77 0.92 103 169 55350040 104375 772691 24967 OBJECT 13.5 35 46 True 23.45 0.45 1.72 0.83 101 170 55350041 101289 768725 24968 OBJECT 13.0 35 56 True 23.19 0.53 1.71 0.90 100 166 55350042 101289 768725 24968 OBJECT 13.5 35 58 True 23.65 0.63 1.71 0.89 94 165 55350043 102988 770833 24969 OBJECT 13.0 35 41 True 22.98 0.42 1.76 0.95 97 171 55350044 102988 770833 24969 OBJECT 13.5 35 41 True 23.46 0.43 1.73 0.89 94 170 55350045 102998 770845 24970 OBJECT 13.5 35 41 True 23.45 0.40 1.71 0.88 28 172 55350046 102998 770845 24970 OBJECT 13.0 35 41 True 22.98 0.40 1.77 0.94 28 171 55350047 102957 770802 24971 OBJECT 13.0 35 49 True 23.17 0.62 1.68 0.89 93 170 55350048 102957 770802 24971 OBJECT 13.5 35 1 True -14.49 0.65 0.30 0.86 94 172 55350049 101242 768702 24972 OBJECT 13.0 35 44 True 23.18 0.63 1.68 0.91 105 171 55350050 101242 768702 24972 OBJECT 13.5 35 49 True 23.64 0.61 1.72 0.89 98 171 55350051 100813 768373 24973 OBJECT 13.0 35 53 True 23.17 0.59 1.69 0.90 99 175 55350052 100813 768373 24973 OBJECT 13.5 35 55 True 23.65 0.61 1.71 0.87 97 168 55350053 102145 770000 24974 OBJECT 13.5 35 56 True 23.44 0.48 1.73 0.88 104 170 55350054 102145 770000 24974 OBJECT 13.0 35 57 True 22.98 0.44 1.77 0.93 106 171 55350055 102145 770000 24974 OBJECT 13.0 35 53 True 23.00 0.45 1.77 0.94 107 170 55350056 102145 770000 24974 OBJECT 13.5 35 52 True 23.46 0.44 1.73 0.90 103 173 55350057 101352 753564 24975 OBJECT 13.5 35 60 True 23.64 0.67 1.70 0.87 98 176 55350058 101352 753564 24975 OBJECT 13.0 35 58 True 23.15 0.64 1.68 0.89 103 177 55350059 101392 753581 24976 OBJECT 13.0 35 6 True 6.50 -5.93 0.30 0.88 101 176 55350060 101392 753581 24976 OBJECT 13.5 35 7 True 7.50 -5.92 0.30 0.87 100 177 55350061 101377 753574 24977 OBJECT 13.0 35 47 True 22.98 0.48 1.76 0.96 101 176 55350062 101377 753574 24977 OBJECT 13.5 35 60 True 23.62 0.51 1.75 0.95 98 176 55350063 101385 753577 24978 OBJECT 13.0 35 49 True 22.97 0.45 1.78 0.91 106 175 55350064 101385 753577 24978 OBJECT 13.5 35 50 True 23.43 0.49 1.72 0.87 103 176 55350065 100111 751887 24979 OBJECT 13.0 35 64 True 23.25 -6.01 1.76 0.87 98 177 55350066 100111 751887 24979 OBJECT 13.5 35 67 True 23.71 -6.00 1.70 0.86 96 180 55350067 103334 755362 24980 OBJECT 13.0 43 52 True 22.97 0.42 1.78 0.93 109 175 55350068 103334 755362 24980 OBJECT 13.5 43 52 True 23.44 0.47 1.74 0.97 105 179 55350069 103334 755363 24981 OBJECT 13.0 43 50 True 22.99 0.45 1.75 0.94 109 178 55350070 103334 755363 24981 OBJECT 13.5 43 53 True 23.44 0.49 1.72 0.90 102 176 55350071 103334 755364 24982 OBJECT 13.0 43 60 True 22.97 0.41 1.77 0.93 106 178 55350072 103334 755364 24982 OBJECT 13.5 43 59 True 23.44 0.47 1.72 0.87 101 177 55350073 103334 755365 24983 OBJECT 13.0 43 63 True 22.97 0.42 1.77 0.92 105 181 55350074 103334 755365 24983 OBJECT 13.5 43 64 True 23.43 0.48 1.74 0.88 102 181 55350075 102400 754391 24984 OBJECT 13.0 43 63 True 23.24 -6.02 1.76 0.89 107 175 55350076 102400 754391 24984 OBJECT 13.5 43 61 True 23.70 -5.95 1.70 0.87 102 177 55350077 102400 754392 24985 OBJECT 13.0 43 65 True 23.24 -5.99 1.74 0.88 105 180 55350078 102400 754392 24985 OBJECT 13.5 43 64 True 23.70 -5.97 1.70 0.84 102 179 55350079 102400 754393 24986 OBJECT 13.0 43 64 True 23.22 -5.97 1.73 0.87 107 180 55350080 102400 754393 24986 OBJECT 13.5 43 63 True 23.68 -5.94 1.68 0.87 102 182 55350081 100550 752796 24987 OBJECT 13.0 35 81 True 22.98 0.48 1.79 0.93 101 179 55350082 100550 752796 24987 OBJECT 13.5 35 75 True 23.70 -6.01 1.74 0.88 100 182 55350083 100550 752796 24987 DOMEFLAT 13.5 5 104 True -- 0.73 -- 0.85 -- -- 55350084 100550 752796 24987 DOMEFLAT 13.5 5 104 True -- 0.74 -- 0.84 -- -- 55350085 100550 752796 24987 DOMEFLAT 13.5 5 104 True -- 0.74 -- 0.85 -- -- num exptype nread mtp1 mtp2 mtp3 mtp4 mtp5 mtp6 mtp7 mtp8 mtp9 mtp10 -------- ---------- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----- 55350003 QUARTZFLAT 10 71 79 88 98 98 92 95 96 97 89 55350011 DOMEFLAT 5 123 132 139 150 167 147 150 163 157 144 55350012 DOMEFLAT 5 83 93 98 105 116 101 103 110 106 101 55350013 DOMEFLAT 5 81 92 96 103 114 100 101 108 104 100 55350014 DOMEFLAT 5 83 94 98 105 116 102 103 110 106 102 55350083 DOMEFLAT 5 74 83 89 97 106 95 97 104 99 95 55350084 DOMEFLAT 5 74 83 89 96 104 94 96 103 98 95 55350085 DOMEFLAT 5 75 84 89 96 105 94 96 103 98 95 ---- Mirror Numbers ---- PRIMARY: -------- Scale: 1.000000 MIGS TONIGHT NOMINAL Axial A: 0.1030 0.1030 Axial B: -0.0300 -0.0250 Axial C: -0.1770 -0.1740 Trans D: -0.0230 -0.0300 Lateral E: 0.3400 0.3400 Lateral F: 0.5475 0.5470 GALILS Commanded: 8450 -1050 8800 22100 -2000 -1700 Actual: 8450 -1050 8800 22100 -2000 -1700 SETMIR VALUES PrimDesOrient: 0.0 2.03 16.67 -410.97 -787.67 PrimOrient: 1.06 2.03 16.67 -410.97 -787.67 SECONDARY: ---------- Focus: 0.0000 Air temp: 0.00 Altitude: 30.0 MIGS TONIGHT NOMINAL Axial A: -7.6390 -7.6390 Axial B: -7.5340 -7.5320 Axial C: -7.5270 -7.5280 Trans D: 0.2040 0.1940 GALILS Commanded: 2249900 2247950 2240550 -1750 -1700 Actual: 2215635 2225468 2199320 -1750 -1700 SETMIR VALUES SecDesOrient: 1757.0 7.9 1.5 -39.3 35.42 SecOrient: 1756.93 7.89 1.48 -39.31 35.18 ---- Focus Log ---- Time Field-Design AZ ALT ROT Focus rms ArcOffX OffY Seeing errRA[prc10,prc90] errDec[prc10,prc90] 01:52 103462-771813 29.99 58.02 236.70 -163 0.184 -3 1 1.48 -0.007[-0.116, 0.100] -0.010[-0.139, 0.151] 02:10 103421-771723 11.42 54.18 221.31 -201 0.199 -1 0 1.65 -0.008[-0.102, 0.108] -0.006[-0.089, 0.070] 02:29 103450-771787 10.85 56.56 221.29 -201 0.166 -3 1 1.49 -0.015[-0.100, 0.092] -0.007[-0.064, 0.110] 02:46 103467-771830 11.78 56.50 223.54 -201 0.178 -3 1 1.70 -0.001[-0.118, 0.142] 0.033[-0.142, 0.161] 03:04 103428-771740 10.80 52.30 224.11 -201 0.143 -2 0 1.69 -0.011[-0.086, 0.108] 0.005[-0.101, 0.115] 03:22 103465-771823 0.73 61.31 214.88 -181 0.150 -6 3 1.51 -0.010[-0.081, 0.101] -0.003[-0.139, 0.148] 03:40 103429-771741 -6.17 50.52 208.73 -181 0.153 -1 3 1.42 -0.021[-0.108, 0.101] -0.011[-0.091, 0.100] 04:00 103400-771682 -3.48 52.80 207.46 -181 0.177 -3 5 1.53 0.022[-0.146, 0.093] 0.003[-0.172, 0.116] 04:18 103401-771684 -12.76 50.01 198.65 -168 0.170 -1 4 1.52 0.022[-0.152, 0.147] 0.001[-0.125, 0.102] 04:36 103395-771671 -7.65 62.41 208.93 -168 0.158 -6 7 1.47 -0.003[-0.114, 0.108] 0.002[-0.070, 0.086] 04:54 104359-772664 -10.90 57.92 206.12 -125 0.161 -4 5 1.70 -0.025[-0.098, 0.174] 0.016[-0.175, 0.112] 05:12 104356-772652 -18.07 52.99 199.75 -80 0.155 -1 4 1.50 -0.010[-0.069, 0.072] -0.017[-0.127, 0.192] 05:31 104375-772691 -5.95 54.35 215.74 -30 0.183 -2 5 1.43 0.004[-0.089, 0.083] 0.036[-0.216, 0.167] 05:49 101289-768725 8.76 56.08 226.35 -7 0.189 -3 6 1.95 0.020[-0.119, 0.122] -0.050[-0.213, 0.218] 06:09 102988-770833 181.84 54.82 24.84 -7 0.236 -1 -8 1.79 0.002[-0.110, 0.096] 0.001[-0.124, 0.152] 06:28 102998-770845 182.80 52.51 30.66 -31 0.223 -1 -7 1.92 0.021[-0.127, 0.134] 0.032[-0.166, 0.150] 06:47 102957-770802 179.63 59.33 33.52 -31 0.224 1 -9 2.26 0.009[-0.184, 0.117] -0.002[-0.203, 0.161] 07:06 101242-768702 8.58 59.53 224.36 -21 0.181 -6 5 1.77 0.005[-0.121, 0.105] -0.035[-0.186, 0.162] 07:24 100813-768373 182.54 52.84 45.14 1 0.175 0 -6 1.74 -0.005[-0.095, 0.098] 0.006[-0.097, 0.104] 07:57 102145-770000 177.43 33.72 -65.35 1 0.284 -4 1 2.19 -0.011[-0.348, 0.368] -0.001[-0.227, 0.182] 08:12 102145-770000 177.49 33.85 -61.78 -15 0.295 -4 1 2.20 0.014[-0.232, 0.197] 0.027[-0.215, 0.169] 08:34 101352-753564 106.03 41.87 268.41 -15 0.212 -6 2 3.18 0.004[-0.110, 0.119] 0.016[-0.193, 0.156] 08:55 101392-753581 96.61 39.77 265.93 -3 0.256 -4 0 2.10 -0.001[-0.255, 0.249] 0.021[-0.199, 0.128] 09:13 101377-753574 95.89 45.75 267.10 -3 0.225 -5 2 2.02 0.008[-0.216, 0.225] -0.004[-0.112, 0.139] 09:34 101385-753577 123.99 46.08 -72.86 -15 0.240 -2 0 1.84 0.060[-0.248, 0.173] 0.001[-0.180, 0.169] 09:54 100111-751887 91.92 32.31 269.93 -15 0.290 -2 -4 2.08 0.015[-0.230, 0.260] -0.039[-0.123, 0.126] 10:17 103334-755362 -32.45 69.31 157.63 -52 0.127 -15 5 1.26 0.011[-0.064, 0.071] -0.002[-0.142, 0.157] 10:37 103334-755363 -43.41 66.72 148.74 -20 0.140 -13 7 1.71 -0.013[-0.129, 0.116] -0.004[-0.285, 0.325] 10:57 103334-755364 -52.41 63.52 141.89 3 0.142 -10 7 1.59 -0.023[-0.147, 0.131] 0.038[-0.167, 0.147] 11:17 103334-755365 -59.64 59.97 136.82 3 0.145 -5 7 2.06 -0.027[-0.122, 0.081] 0.012[-0.241, 0.224] 11:39 102400-754391 -36.16 65.38 158.82 3 0.167 -11 6 1.16 -0.015[-0.097, 0.150] 0.033[-0.160, 0.228] 11:59 102400-754392 -45.34 62.65 151.60 -10 0.165 -9 6 1.25 0.030[-0.146, 0.131] -0.038[-0.134, 0.153] 12:20 102400-754393 -53.19 59.39 145.80 -10 0.201 -5 7 1.26 -0.008[-0.153, 0.169] -0.053[-0.214, 0.212] ---- Telescope Status ---- 00:00Z Started ventilation 01:03Z encl25m : open 13:14Z encl25m : closed No interlocks bypassed Status at: 13:19Z Telescope stowed at: 121.0, 30.0, 0.0 mount Instrument mounted: FPS Counterweights at: n/a, FPS balanced LN2 autofill systems: Connected and turned on 180L LN2 dewar scales: SP1 248 lbs, 23 psi FPS Status ========== CP10 Loop = 7.36 L/min GFA Loop = 2.36 L/min Supply pressure = 44.8 psi Return pressure = 29.4 psi Chiller Status ============== Set temperarature = 5.5 C Flow = 4.8 Gpm ---- Software Used ---- STUI : 1.7.19 alerts : 2.3.0 boss : 6.0.5a1 -boss.specMec : 3.0.4 apo : 4.1.0 fliswarm : 0.6.0 jaeger : 1.11.0 kaiju : 1.4.1 coordio : 1.18.1 fps_calibrati : 2025.12.04 cherno : 1.1.0 astrometrynet : 0.93 hal : 1.4.1 hartmann : 2.0.2 hub : 5.0.1a0 mcp : 2.3.1 -mcp.plc : 35 -mcp.azFiduci : v1_153 -mcp.altFiduc : v1_153 -mcp.rotFiduc : v1_153 tcc : 1.4.0 apogee : not availble apogeecal : not availble apogeeql : v1_7_0dev Boson : 0.5.1 --------------Other Versions-------------- sdss-obstools : 3.9.3 TPM : 1.2-31-gd7eb MCP : 2.3.1 idlspec2d : v6_2_1 Kronos : 2.1.0a roboscheduler : 2.1.0 /dev/sdb1 2.0T 491G 1.6T 24% /home /dev/sdd1 22T 17T 4.1T 81% /data ---- APOGEE Data Summary ---- Last morning's calibrations look OK: 61096 90 13:11 55340090 Dark 60 B 13.5 ---------- a-b-c - - 61096 91 13:21 55340091 Dark 60 B 13.5 ---------- a-b-c - - 61096 92 13:32 55340092 Dark 60 B 13.5 ---------- a-b-c - - 61096 93 13:34 55340093 QuarFlat 10 B 13.5 ---------- a-b-c - 101 61096 94 13:36 55340094 QuarFlat 10 B 13.5 ---------- a-b-c - 101 61096 95 13:37 55340095 QuarFlat 10 B 13.5 ---------- a-b-c - 101 61096 96 13:40 55340096 Arc-Thar 12 B 13.5 ---------- a-b-c 0.59 101 61096 97 13:47 55340097 Arc-Une 40 B 13.5 ---------- a-b-c 0.61 102 61096 98 13:49 55340098 Arc-Thar 12 A 13.0 ---------- a-b-c 0.09 104 61096 99 13:56 55340099 Arc-Une 40 A 13.0 ---------- a-b-c 0.12 103 61096 100 14:02 55340100 Dark 30 A 13.0 ---------- a-b-c - - 61096 101 14:07 55340101 InteFlat 30 A 13.0 ---------- a-b-c - - 61096 102 14:13 55340102 InteFlat 30 A 13.0 ---------- a-b-c - - 61096 103 14:18 55340103 InteFlat 30 A 13.0 ---------- a-b-c - - 61096 104 14:23 55340104 Dark 30 A 13.0 ---------- a-b-c - - 61096 105 14:29 55340105 Arc---- 30 A 13.0 ---------- a-b-c - 102 FPI A 61096 106 14:34 55340106 Arc---- 30 B 13.5 ---------- a-b-c - 97 FPI B APOGEE data list, mjd=61097, all raw_data: /data/apogee/utr_cdr/61097/apRaw-*.fits archive: /data/apogee/archive/61097/apR-[a,b,c]-*.apz quickred: /data/apogee/quickred/61097/apq-*.fits ------------------------------------------------------------------------------ mjd i UT File/Exp Imtype Nread A/B Dth Design-Cfg Arch Offset %Flux/FPI Comm ------------------------------------------------------------------------------ 61097 1 23:02 55350001 Arc---- 3 B 13.5 ---------- a-b-c - -23 test 61097 2 23:16 55350002 Dark 60 B 13.5 ---------- a-b-c - - 61097 3 23:18 55350003 QuarFlat 10 B 13.5 ---------- a-b-c - 101 61097 4 23:20 55350004 Arc-Thar 12 B 13.5 ---------- a-b-c 0.58 101 61097 5 23:27 55350005 Arc-Une 40 B 13.5 ---------- a-b-c 0.60 103 61097 6 23:29 55350006 Arc-Thar 12 A 13.0 ---------- a-b-c 0.04 101 61097 7 23:37 55350007 Arc-Une 40 A 13.0 ---------- a-b-c 0.11 103 61097 8 23:48 55350008 Dark 60 A 13.0 ---------- a-b-c - - 61097 9 23:53 55350009 Arc---- 30 A 13.0 ---------- a-b-c - 102 FPI A 61097 10 23:58 55350010 Arc---- 30 B 13.5 ---------- a-b-c - 99 FPI B 61097 11 01:07 55350011 DomeFlat 5 B 13.5 -999-24953 a-b-c - 235 61097 12 01:17 55350012 DomeFlat 5 B 13.5 -999-24953 a-b-c - 154 61097 13 01:18 55350013 DomeFlat 5 B 13.5 -999-24953 a-b-c - 151 61097 14 01:20 55350014 DomeFlat 5 B 13.5 -999-24953 a-b-c - 154 61097 15 01:58 55350015 Object 35 A 13.0 771813-24955 a-b-c 0.13 1,1 61097 16 02:04 55350016 Object 35 B 13.5 771813-24955 a-b-c 0.61 1,1 61097 17 02:16 55350017 Object 35 A 13.0 771723-24956 a-b-c 0.15 1,1 61097 18 02:22 55350018 Object 35 B 13.5 771723-24956 a-b-c 0.62 1,1 61097 19 02:34 55350019 Object 35 A 13.0 771787-24957 a-b-c 0.13 1,1 61097 20 02:40 55350020 Object 35 B 13.5 771787-24957 a-b-c 0.61 1,1 61097 21 02:52 55350021 Object 35 A 13.0 771830-24958 a-b-c 0.13 1,1 61097 22 02:58 55350022 Object 35 B 13.5 771830-24958 a-b-c 0.61 1,1 61097 23 03:10 55350023 Object 35 A 13.0 771740-24959 a-b-c 0.13 1,1 61097 24 03:16 55350024 Object 35 B 13.5 771740-24959 a-b-c 0.61 1,1 61097 25 03:28 55350025 Object 35 A 13.0 771823-24960 a-b-c 0.13 1,1 61097 26 03:34 55350026 Object 35 B 13.5 771823-24960 a-b-c 0.61 1,1 61097 27 03:46 55350027 Object 35 A 13.0 771741-24961 a-b-c 0.12 1,1 61097 28 03:52 55350028 Object 35 B 13.5 771741-24961 a-b-c 0.61 1,1 61097 29 04:05 55350029 Object 35 B 13.5 771682-24962 a-b-c 0.61 1,1 61097 30 04:12 55350030 Object 35 A 13.0 771682-24962 a-b-c 0.13 1,1 61097 31 04:24 55350031 Object 35 A 13.0 771684-24963 a-b-c 0.14 1,1 61097 32 04:30 55350032 Object 35 B 13.5 771684-24963 a-b-c 0.62 1,1 61097 33 04:42 55350033 Object 35 A 13.0 771671-24964 a-b-c 0.12 1,1 61097 34 04:48 55350034 Object 35 B 13.5 771671-24964 a-b-c 0.60 1,1 61097 35 05:00 55350035 Object 35 A 13.0 772664-24965 a-b-c 0.12 1,1 61097 36 05:06 55350036 Object 35 B 13.5 772664-24965 a-b-c 0.60 1,1 61097 37 05:18 55350037 Object 35 A 13.0 772652-24966 a-b-c 0.13 1,1 61097 38 05:24 55350038 Object 35 B 13.5 772652-24966 a-b-c 0.60 1,1 61097 39 05:37 55350039 Object 35 A 13.0 772691-24967 a-b-c 0.15 1,1 61097 40 05:43 55350040 Object 35 B 13.5 772691-24967 a-b-c 0.64 1,1 61097 41 05:55 55350041 Object 35 A 13.0 768725-24968 a-b-c 0.13 1,1 61097 42 06:01 55350042 Object 35 B 13.5 768725-24968 a-b-c 0.60 1,1 61097 43 06:14 55350043 Object 35 A 13.0 770833-24969 a-b-c 0.06 1,1 61097 44 06:21 55350044 Object 35 B 13.5 770833-24969 a-b-c 0.53 1,1 61097 45 06:34 55350045 Object 35 B 13.5 770845-24970 a-b-c 0.60 1,1 61097 46 06:40 55350046 Object 35 A 13.0 770845-24970 a-b-c 0.12 1,1 61097 47 06:53 55350047 Object 35 A 13.0 770802-24971 a-b-c 0.12 1,1 61097 48 06:59 55350048 Object 35 B 13.5 770802-24971 a-b-c 0.59 1,1 61097 49 07:11 55350049 Object 35 A 13.0 768702-24972 a-b-c 0.13 1,1 61097 50 07:18 55350050 Object 35 B 13.5 768702-24972 a-b-c 0.60 1,1 61097 51 07:30 55350051 Object 35 A 13.0 768373-24973 a-b-c 0.34 1,1 61097 52 07:36 55350052 Object 35 B 13.5 768373-24973 a-b-c 0.60 1,1 61097 53 08:03 55350053 Object 35 B 13.5 770000-24974 a-b-c 0.59 1,1 61097 54 08:09 55350054 Object 35 A 13.0 770000-24974 a-b-c 0.12 1,1 61097 55 08:17 55350055 Object 35 A 13.0 770000-24974 a-b-c 0.12 1,1 61097 56 08:23 55350056 Object 35 B 13.5 770000-24974 a-b-c 0.60 1,1 61097 57 08:40 55350057 Object 35 B 13.5 753564-24975 a-b-c 0.18 1,1 61097 58 08:46 55350058 Object 35 A 13.0 753564-24975 a-b-c -0.29 1,1 61097 59 09:01 55350059 Object 35 A 13.0 753581-24976 a-b-c 0.12 1,1 61097 60 09:07 55350060 Object 35 B 13.5 753581-24976 a-b-c 0.60 1,1 61097 61 09:19 55350061 Object 35 A 13.0 753574-24977 a-b-c 0.13 1,1 61097 62 09:25 55350062 Object 35 B 13.5 753574-24977 a-b-c 0.60 1,1 61097 63 09:39 55350063 Object 35 A 13.0 753577-24978 a-b-c 0.12 1,1 61097 64 09:46 55350064 Object 35 B 13.5 753577-24978 a-b-c 0.60 1,1 61097 65 09:59 55350065 Object 35 A 13.0 751887-24979 a-b-c 0.12 1,1 61097 66 10:06 55350066 Object 35 B 13.5 751887-24979 a-b-c 0.60 1,1 61097 67 10:24 55350067 Object 43 A 13.0 755362-24980 a-b-c 0.13 1,1 61097 68 10:31 55350068 Object 43 B 13.5 755362-24980 a-b-c 0.60 1,1 61097 69 10:44 55350069 Object 43 A 13.0 755363-24981 a-b-c 0.13 1,1 61097 70 10:51 55350070 Object 43 B 13.5 755363-24981 a-b-c 0.60 1,1 61097 71 11:04 55350071 Object 43 A 13.0 755364-24982 a-b-c 0.13 1,1 61097 72 11:12 55350072 Object 43 B 13.5 755364-24982 a-b-c 0.60 1,1 61097 73 11:25 55350073 Object 43 A 13.0 755365-24983 a-b-c 0.13 1,1 61097 74 11:32 55350074 Object 43 B 13.5 755365-24983 a-b-c 0.60 1,1 61097 75 11:47 55350075 Object 43 A 13.0 754391-24984 a-b-c 0.13 1,1 61097 76 11:54 55350076 Object 43 B 13.5 754391-24984 a-b-c 0.61 1,1 61097 77 12:06 55350077 Object 43 A 13.0 754392-24985 a-b-c 0.13 1,1 61097 78 12:14 55350078 Object 43 B 13.5 754392-24985 a-b-c 0.60 1,1 61097 79 12:27 55350079 Object 43 A 13.0 754393-24986 a-b-c 0.12 1,1 61097 80 12:34 55350080 Object 43 B 13.5 754393-24986 a-b-c 0.60 1,1 61097 81 12:47 55350081 Object 35 A 13.0 752796-24987 a-b-c 0.13 1,1 ... ------------------------------------------------------------------------------ ---- BOSS Data Summary ---- Reading FITS from /data/spectro//61097 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - n Time Filename design-field cfg flav shu Exp colA colB colC Hrt - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 23:02 b1-00396879 ----------- ---- bia Clo 0.0 -766 -754 -720 2 23:02 r1-00396879 ----------- ---- bia Clo 0.0 -766 -754 -720 3 23:04 b1-00396880 ----------- ---- dar Clo 20.0 -766 -754 -720 4 23:04 r1-00396880 ----------- ---- dar Clo 20.0 -766 -754 -720 5 23:53 r1-00396881 -999--999 24953 arc Lef 4.1 -766 -754 -720 HART 6 23:53 b1-00396881 -999--999 24953 arc Lef 4.1 -766 -754 -720 HART 7 23:54 b1-00396882 -999--999 24953 arc Rig 4.1 -766 -754 -720 HART 8 23:54 r1-00396882 -999--999 24953 arc Rig 4.1 -766 -754 -720 HART 9 23:55 r1-00396883 -999--999 24953 arc Out 4.1 -2204 -2192 -2160 10 23:55 b1-00396883 -999--999 24953 arc Out 4.1 -2204 -2192 -2160 11 23:57 b1-00396884 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 12 23:57 r1-00396884 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 13 01:20 b1-00396885 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 14 01:20 r1-00396885 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 15 01:22 b1-00396886 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 16 01:22 r1-00396886 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 17 01:24 b1-00396887 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 18 01:24 r1-00396887 -999--999 24953 fla Out 25.1 -2204 -2192 -2160 19 01:30 r1-00396888 752081-100281 24954 arc Lef 4.1 -2204 -2192 -2160 HART 20 01:30 b1-00396888 752081-100281 24954 arc Lef 4.1 -2204 -2192 -2160 HART 21 01:30 b1-00396889 752081-100281 24954 arc Rig 4.1 -2204 -2192 -2160 HART 22 01:30 r1-00396889 752081-100281 24954 arc Rig 4.1 -2204 -2192 -2160 HART 23 01:31 b1-00396890 752081-100281 24954 arc Out 4.1 112 124 155 24 01:31 r1-00396890 752081-100281 24954 arc Out 4.1 112 124 155 25 01:50 r1-00396891 771813-103462 24955 arc Out 4.1 112 124 155 26 01:50 b1-00396891 771813-103462 24955 arc Out 4.1 112 124 155 27 01:52 r1-00396892 771813-103462 24955 sci Out 730.1 112 124 155 28 01:52 b1-00396892 771813-103462 24955 sci Out 730.1 112 124 155 29 02:09 b1-00396893 771723-103421 24956 arc Out 4.1 112 124 155 30 02:09 r1-00396893 771723-103421 24956 arc Out 4.1 112 124 155 31 02:10 r1-00396894 771723-103421 24956 sci Out 730.1 112 124 155 32 02:10 b1-00396894 771723-103421 24956 sci Out 730.1 112 124 155 33 02:27 r1-00396895 771787-103450 24957 arc Out 4.1 112 124 155 34 02:27 b1-00396895 771787-103450 24957 arc Out 4.1 112 124 155 35 02:29 r1-00396896 771787-103450 24957 sci Out 730.1 112 124 155 36 02:29 b1-00396896 771787-103450 24957 sci Out 730.1 112 124 155 37 02:45 r1-00396897 771830-103467 24958 arc Out 4.1 112 124 155 38 02:45 b1-00396897 771830-103467 24958 arc Out 4.1 112 124 155 39 02:46 b1-00396898 771830-103467 24958 sci Out 730.1 112 124 155 40 02:46 r1-00396898 771830-103467 24958 sci Out 730.1 112 124 155 41 03:02 b1-00396899 771740-103428 24959 arc Out 4.1 112 124 155 42 03:02 r1-00396899 771740-103428 24959 arc Out 4.1 112 124 155 43 03:04 r1-00396900 771740-103428 24959 sci Out 730.1 112 124 155 44 03:04 b1-00396900 771740-103428 24959 sci Out 730.1 112 124 155 45 03:21 b1-00396901 771823-103465 24960 arc Out 4.1 112 124 155 46 03:21 r1-00396901 771823-103465 24960 arc Out 4.1 112 124 155 47 03:22 b1-00396902 771823-103465 24960 sci Out 730.1 112 124 155 48 03:22 r1-00396902 771823-103465 24960 sci Out 730.1 112 124 155 49 03:39 b1-00396903 771741-103429 24961 arc Out 4.1 112 124 155 50 03:39 r1-00396903 771741-103429 24961 arc Out 4.1 112 124 155 51 03:40 b1-00396904 771741-103429 24961 sci Out 730.1 112 124 155 52 03:40 r1-00396904 771741-103429 24961 sci Out 730.1 112 124 155 53 03:58 b1-00396905 771682-103400 24962 arc Out 4.1 112 124 155 54 03:58 r1-00396905 771682-103400 24962 arc Out 4.1 112 124 155 55 04:00 b1-00396906 771682-103400 24962 sci Out 730.1 112 124 155 56 04:00 r1-00396906 771682-103400 24962 sci Out 730.1 112 124 155 57 04:16 b1-00396907 771684-103401 24963 arc Out 4.1 112 124 155 58 04:16 r1-00396907 771684-103401 24963 arc Out 4.1 112 124 155 59 04:18 b1-00396908 771684-103401 24963 sci Out 730.1 112 124 155 60 04:18 r1-00396908 771684-103401 24963 sci Out 730.1 112 124 155 61 04:34 r1-00396909 771671-103395 24964 arc Out 4.1 112 124 155 62 04:34 b1-00396909 771671-103395 24964 arc Out 4.1 112 124 155 63 04:36 b1-00396910 771671-103395 24964 sci Out 730.1 112 124 155 64 04:36 r1-00396910 771671-103395 24964 sci Out 730.1 112 124 155 65 04:52 b1-00396911 772664-104359 24965 arc Out 4.1 112 124 155 66 04:52 r1-00396911 772664-104359 24965 arc Out 4.1 112 124 155 67 04:54 b1-00396912 772664-104359 24965 sci Out 730.1 112 124 155 68 04:54 r1-00396912 772664-104359 24965 sci Out 730.1 112 124 155 69 05:10 b1-00396913 772652-104356 24966 arc Out 4.1 112 124 155 70 05:10 r1-00396913 772652-104356 24966 arc Out 4.1 112 124 155 71 05:12 b1-00396914 772652-104356 24966 sci Out 730.1 112 124 155 72 05:12 r1-00396914 772652-104356 24966 sci Out 730.1 112 124 155 73 05:29 r1-00396915 772691-104375 24967 arc Out 4.1 112 124 155 74 05:29 b1-00396915 772691-104375 24967 arc Out 4.1 112 124 155 75 05:31 r1-00396916 772691-104375 24967 sci Out 730.1 112 124 155 76 05:31 b1-00396916 772691-104375 24967 sci Out 730.1 112 124 155 77 05:47 r1-00396917 768725-101289 24968 arc Out 4.1 112 124 155 78 05:47 b1-00396917 768725-101289 24968 arc Out 4.1 112 124 155 79 05:49 r1-00396918 768725-101289 24968 sci Out 730.1 112 124 155 80 05:49 b1-00396918 768725-101289 24968 sci Out 730.1 112 124 155 81 06:06 r1-00396919 770833-102988 24969 arc Out 4.1 112 124 155 82 06:06 b1-00396919 770833-102988 24969 arc Out 4.1 112 124 155 83 06:09 r1-00396920 770833-102988 24969 sci Out 730.1 112 124 155 84 06:09 b1-00396920 770833-102988 24969 sci Out 730.1 112 124 155 85 06:26 b1-00396921 770845-102998 24970 arc Out 4.1 112 124 155 86 06:26 r1-00396921 770845-102998 24970 arc Out 4.1 112 124 155 87 06:28 r1-00396922 770845-102998 24970 sci Out 730.1 112 124 155 88 06:28 b1-00396922 770845-102998 24970 sci Out 730.1 112 124 155 89 06:45 b1-00396923 770802-102957 24971 arc Out 4.1 112 124 155 90 06:45 r1-00396923 770802-102957 24971 arc Out 4.1 112 124 155 91 06:47 r1-00396924 770802-102957 24971 sci Out 730.1 112 124 155 92 06:47 b1-00396924 770802-102957 24971 sci Out 730.1 112 124 155 93 07:03 r1-00396925 768702-101242 24972 arc Out 4.1 112 124 155 94 07:03 b1-00396925 768702-101242 24972 arc Out 4.1 112 124 155 95 07:06 r1-00396926 768702-101242 24972 sci Out 730.1 112 124 155 96 07:06 b1-00396926 768702-101242 24972 sci Out 730.1 112 124 155 97 07:22 r1-00396927 768373-100813 24973 arc Out 4.1 112 124 155 98 07:22 b1-00396927 768373-100813 24973 arc Out 4.1 112 124 155 99 07:24 r1-00396928 768373-100813 24973 sci Out 730.1 112 124 155 100 07:24 b1-00396928 768373-100813 24973 sci Out 730.1 112 124 155 101 07:40 r1-00396929 770000-102145 24974 arc Out 4.1 112 124 155 102 07:40 b1-00396929 770000-102145 24974 arc Out 4.1 112 124 155 103 07:57 b1-00396930 770000-102145 24974 sci Out 730.1 112 124 155 104 07:57 r1-00396930 770000-102145 24974 sci Out 730.1 112 124 155 105 08:12 b1-00396931 770000-102145 24974 sci Out 730.1 112 124 155 106 08:12 r1-00396931 770000-102145 24974 sci Out 730.1 112 124 155 107 08:30 r1-00396932 753564-101352 24975 arc Out 4.1 112 124 155 108 08:30 b1-00396932 753564-101352 24975 arc Out 4.1 112 124 155 109 08:34 r1-00396933 753564-101352 24975 sci Out 730.1 112 124 155 110 08:34 b1-00396933 753564-101352 24975 sci Out 730.1 112 124 155 111 08:48 r1-00396934 753564-101352 24975 fla Out 25.1 112 124 155 112 08:48 b1-00396934 753564-101352 24975 fla Out 25.1 112 124 155 113 08:52 b1-00396935 753581-101392 24976 arc Lef 4.1 112 124 155 HART 114 08:52 r1-00396935 753581-101392 24976 arc Lef 4.1 112 124 155 HART 115 08:52 b1-00396936 753581-101392 24976 arc Rig 4.1 112 124 155 HART 116 08:52 r1-00396936 753581-101392 24976 arc Rig 4.1 112 124 155 HART 117 08:54 b1-00396937 753581-101392 24976 arc Out 4.1 -1153 -1139 -1108 118 08:54 r1-00396937 753581-101392 24976 arc Out 4.1 -1153 -1139 -1108 119 08:55 b1-00396938 753581-101392 24976 sci Out 730.1 -1153 -1139 -1108 120 08:55 r1-00396938 753581-101392 24976 sci Out 730.1 -1153 -1139 -1108 121 09:12 r1-00396939 753574-101377 24977 arc Out 4.1 -1153 -1139 -1108 122 09:12 b1-00396939 753574-101377 24977 arc Out 4.1 -1153 -1139 -1108 123 09:13 r1-00396940 753574-101377 24977 sci Out 730.1 -1153 -1139 -1108 124 09:13 b1-00396940 753574-101377 24977 sci Out 730.1 -1153 -1139 -1108 125 09:31 b1-00396941 753577-101385 24978 arc Out 4.1 -1153 -1139 -1108 126 09:31 r1-00396941 753577-101385 24978 arc Out 4.1 -1153 -1139 -1108 127 09:34 b1-00396942 753577-101385 24978 sci Out 730.1 -1153 -1139 -1108 128 09:34 r1-00396942 753577-101385 24978 sci Out 730.1 -1153 -1139 -1108 129 09:51 r1-00396943 751887-100111 24979 arc Out 4.1 -1153 -1139 -1108 130 09:51 b1-00396943 751887-100111 24979 arc Out 4.1 -1153 -1139 -1108 131 09:54 r1-00396944 751887-100111 24979 sci Out 730.1 -1153 -1139 -1108 132 09:54 b1-00396944 751887-100111 24979 sci Out 730.1 -1153 -1139 -1108 133 10:11 r1-00396945 755362-103334 24980 fla Out 25.1 -1153 -1139 -1108 134 10:11 b1-00396945 755362-103334 24980 fla Out 25.1 -1153 -1139 -1108 135 10:14 r1-00396946 755362-103334 24980 arc Out 4.1 -1153 -1139 -1108 136 10:14 b1-00396946 755362-103334 24980 arc Out 4.1 -1153 -1139 -1108 137 10:17 r1-00396947 755362-103334 24980 sci Out 900.1 -1153 -1139 -1108 138 10:17 b1-00396947 755362-103334 24980 sci Out 900.1 -1153 -1139 -1108 139 10:37 r1-00396948 755363-103334 24981 sci Out 900.1 -1153 -1139 -1108 140 10:37 b1-00396948 755363-103334 24981 sci Out 900.1 -1153 -1139 -1108 141 10:57 b1-00396949 755364-103334 24982 sci Out 900.1 -1153 -1139 -1108 142 10:57 r1-00396949 755364-103334 24982 sci Out 900.1 -1153 -1139 -1108 143 11:17 r1-00396950 755365-103334 24983 sci Out 900.1 -1153 -1139 -1108 144 11:17 b1-00396950 755365-103334 24983 sci Out 900.1 -1153 -1139 -1108 145 11:36 b1-00396951 754391-102400 24984 arc Out 4.1 -1153 -1139 -1108 146 11:36 r1-00396951 754391-102400 24984 arc Out 4.1 -1153 -1139 -1108 147 11:39 b1-00396952 754391-102400 24984 sci Out 900.1 -1153 -1139 -1108 148 11:39 r1-00396952 754391-102400 24984 sci Out 900.1 -1153 -1139 -1108 149 11:59 r1-00396953 754392-102400 24985 sci Out 900.1 -1153 -1139 -1108 150 11:59 b1-00396953 754392-102400 24985 sci Out 900.1 -1153 -1139 -1108 151 12:20 r1-00396954 754393-102400 24986 sci Out 900.1 -1153 -1139 -1108 152 12:20 b1-00396954 754393-102400 24986 sci Out 900.1 -1153 -1139 -1108 153 12:39 r1-00396955 752796-100550 24987 arc Out 4.1 -1153 -1139 -1108 154 12:39 b1-00396955 752796-100550 24987 arc Out 4.1 -1153 -1139 -1108 155 12:42 r1-00396956 752796-100550 24987 sci Out 730.1 -1153 -1139 -1108 156 12:42 b1-00396956 752796-100550 24987 sci Out 730.1 -1153 -1139 -1108 ---- BOSS Spectrographs Collimation ---- Time TSP1 R1 B1 Move1 B1Resid ============================================= 23:54:40 6.2 -1979 2.8 -1439 -1.7 01:31:20 6.1 2638 -6.2 2315 1.0 08:53:30 4.7 -989 4.8 -1265 0.9 ---- Weather Log ---- Wind 1 um DIMM IRSC Time Temp C Dewp C MPH Dir Dust fwhm mean sigma 19:00 10.4 -3.1 8.4 69.5 282 19:15 10.2 -3.6 17.1 92.5 300 19:30 10.7 -3.0 18.1 02.5 268 19:45 11.0 -3.0 6.1 68.0 234 20:00 11.6 -2.3 18.9 95.5 279 20:15 10.6 -3.3 19.3 04.8 274 20:30 11.4 -3.3 9.3 70.0 258 20:45 12.0 -2.5 11.0 16.8 288 21:00 10.9 -3.6 21.3 92.7 273 21:15 11.5 -2.8 12.0 02.3 259 21:30 11.6 -2.9 11.7 87.0 324 21:45 12.4 -3.6 16.0 79.2 279 22:00 12.0 -3.3 19.7 83.4 188 22:15 14.6 -3.1 17.2 66.6 208 22:30 12.7 -2.8 15.1 70.4 236 22:45 12.4 -3.3 13.8 98.4 257 23:00 12.2 -3.3 10.2 65.0 292 23:15 12.4 -3.2 9.4 68.1 348 23:30 13.1 -3.3 16.3 64.8 346 23:45 12.4 -3.0 15.8 58.0 383 00:00 11.5 -3.7 12.2 64.1 376 00:15 11.3 -3.7 14.8 65.5 411 00:30 11.1 -3.8 10.1 63.5 459 00:45 10.9 -3.8 11.4 75.2 461 01:00 11.0 -3.8 16.1 73.3 501 01:15 10.8 -3.7 13.0 71.4 524 01:30 10.8 -3.6 15.8 78.3 506 342 25.93 01:45 10.9 -3.3 14.0 70.0 569 343 27.27 02:00 10.9 -3.1 10.5 68.0 786 343 22.89 02:15 10.7 -3.3 14.0 67.0 841 340 35.35 02:30 10.9 -3.1 12.6 85.1 878 341 20.15 02:45 10.6 -3.1 13.5 78.8 985 343 25.87 03:00 10.7 -3.1 9.2 15.1 874 342 26.74 03:15 10.7 -3.0 19.0 03.4 750 340 20.40 03:30 10.6 -3.0 6.1 72.5 723 343 31.51 03:45 10.8 -3.1 14.6 17.6 485 340 18.15 04:00 10.7 -3.2 19.2 14.1 452 341 17.07 04:15 10.2 -3.1 24.1 19.3 411 341 14.90 04:30 10.7 -3.3 8.9 13.1 366 340 9.19 04:45 10.3 -3.3 15.0 42.5 432 341 9.08 05:00 10.3 -3.3 11.0 22.6 401 341 7.83 05:15 9.9 -3.1 10.4 11.3 374 341 5.31 05:30 9.6 -3.1 19.9 28.5 355 342 15.25 05:45 9.3 -3.1 16.1 22.0 343 341 11.78 06:00 9.0 -2.8 12.7 50.0 283 341 9.81 06:15 9.1 -2.8 19.4 33.6 301 341 20.67 06:30 8.7 -2.8 8.1 58.0 262 341 13.86 06:45 9.0 -2.7 14.0 13.5 219 342 34.30 07:00 8.7 -2.7 4.7 00.3 306 341 10.84 07:15 8.7 -2.6 8.4 68.0 238 341 18.56 07:30 8.3 -2.5 18.0 43.2 214 341 9.85 07:45 8.2 -2.5 27.9 33.6 212 342 7.82 08:00 7.7 -2.4 9.2 54.6 195 341 12.66 08:15 7.8 -2.3 3.3 27.0 194 341 7.79 08:30 7.6 -2.2 12.5 56.5 230 342 5.98 08:45 7.3 -2.2 7.4 36.8 198 342 6.33 09:00 7.7 -2.2 15.3 53.8 174 341 7.45 09:15 7.5 -2.0 11.4 7.1 223 341 4.80 09:30 7.7 -2.1 14.0 55.6 206 342 6.21 09:45 8.2 -2.2 10.7 1.8 197 341 7.43 10:00 8.2 -2.3 13.0 31.1 190 342 7.49 10:15 7.5 -2.3 16.0 0.5 200 342 8.99 10:30 7.3 -2.3 7.9 80.1 233 342 17.43 10:45 7.3 -2.2 21.8 52.4 265 344 20.56 11:00 7.1 -2.2 10.4 26.7 232 342 14.64 11:15 7.2 -2.2 22.5 4.0 231 342 11.36 11:30 7.5 -2.7 4.3 99.2 224 342 26.20 11:45 7.5 -2.8 5.5 45.0 207 341 17.21 12:00 7.5 -2.7 7.1 10.4 227 342 20.20 12:15 7.5 -2.8 11.6 24.0 216 343 13.47 12:30 7.2 -2.7 6.9 51.6 186 341 18.20 ---- Time Tracking ---- *=*=*= Observatory: APO *=*=*= MJD: 61097 Fill night time in Hours below *=*=*= Total bright time : 8.4 *=*=*= Bright time, queued observations : 8.6 *=*=*= Bright time, commissioning/engineering: 0.2 *=*=*= Bright time lost to weather : 0 *=*=*= Bright time lost to technical issues : 0 *=*=*= Total dark time : 2.2 *=*=*= Dark time, queued observations : 2.3 *=*=*= Dark time, commissioning/engineering : 0 *=*=*= Dark time lost to weather : 0 *=*=*= Dark time lost to technical issues : 0