Date: Sat, 05 Jun 2021 15:10:46 -0600 Subject: Re: 2.5m obslog 20210604 (SJD 59370) From: Fred Mrozek Dylan, I looked at the CW motion control box about an hour ago (today, Saturday af= ternoon) and those were all reading in the same, correct range around or a l= ittle less than 480 units. --Fred =EF=BB=BFOn 6/5/21, 1:58 PM, "Dylan Gatlin" wrote: According to the Influx archives, it looks like the counterweight moved= =20 around noon on Thursday. It moved a few minutes before altitude was=20 slewed to 90, probably as soon as a stop button was disengaged. On 6/5/21 5:14 AM, kpan@apo.nmsu.edu wrote: > 1. All four counter weights have similar settings in the control box,= a visual > check confirmed they are at the similar height. However, TPM shows cw= #2 is at > 238 while the other three at 481. --=20 print('-Dylan Gatlin')