Subject: Re: [sloan-25mlog 5200] 2.5m obslog 20201016 (SJD 59139) From: John Date: Sat, 17 Oct 2020 07:36:24 -0600 On 10/17/20 6:04 AM, kpan@apo.nmsu.edu wrote: > APACHE POINT OBSERVATORY SDSS 2.5M > > OBSERVING LOG > Friday October 16, 2020 > > (SJD 59139) > > ---- Observing Team ---- > > Kaike Pan > Karen Kinemuchi > > Jose Sanche-Gallego (online) > Hector Javier Ibarra Medel (SOS). > > ---- Observing Plan ---- > > BOSS cameras Shakedown tasks, take a set of focus sweep test data to R1 determine shim shape. > > > ---- Observing Summary ---- > > It was a busy night, fought with issues. > Jose worked on a new version of SOP, in which hartmann works with SP1 only. > Hector spent most of the night to debug the SOS code and have it reduced the > data properly. > > We focused boss cameras. > > Measured the tilts of fiber images, and found that b1 is 0.01 deg away from the > perfect orientation while r1 is 0.15 deg off. Both cameras are within the > tolerance of 0.5 deg, no rotation is needed. > > Home SP1 collimator, zero the position at the lowest position. > > Checked the boss slithead on cartridge 1. It is SP2 slithead from cart 11. > Hector entered the info into the SOS pipeline. Need to give him slithead > info for other cartridges. Conversion log is here: https://wiki.sdss.org/display/SE/Cartridge+Inventory%2C+Conversion%2C+Plate+Plan > > Adjust spectrum position on the detectors, XMID and WaveMid. > > Took a set of focus sweep data. The data was taken without collimator position > feedback on BOSS instrument GUI. > > Took APOGEE evening and morning cal. They both are fine. > > BOSS camera temperatures are checked periodically. They are very stable. > > Notes: > ====== > 1. We could not connect to the guider camera (see log). "ping" command returns > unreachable. We'll add that to the list for mop up items next week. > > 2. Likely, we need a thicker shim on r1. (see log body). > > 3. Because of the blowtorch issue on the old r1, the substrate voltage was set > to 40 V. It is currently set to 40V.Now we have the spare red camera installed. > Should the substrate voltage be changed to the normal setting? Yes it should be changed.  In the past Connie has done this, best bet is to email her. > > 4. SOS complaints about high r1 bias level: r1 Amp 0 high read noise = 3.56. > > 5. Weather data from APO actor doesn't propagate to fit headers. > > 6. Alerts actor shows a half dozen ok messages, e.g.: camCheck.SP1MicroNotTalking > at 2020-10-17 06:05:48 UT found 'Reported by camCheck'. "boss ackErrors" does > not clean these texts. > > 7. Because the sensor for spectr corrector in place doesn't work, auto-mode of > the instrument change doesn't work. This is one of the repair tasks planned for next week. > > 8. Boss complaints about invlidKeyWordData: > 07:22:55 InvalidKeywordData=boss.motorStatus, ['0xff', '0xff', '0xff'] > 07:22:55 InvalidKeywordData=boss.motorPosition, ['-9999999', '-9999999', '-9999999'] > 07:22:55 InvalidKeywordData=boss.shutterStatus, ['0x00'] > 07:22:55 InvalidKeywordData=boss.screenStatus, ['0x00']. > > 9. boss moveColl commands fail while the collimator likely moves to the > commanded positions. Shutter and hartmann doors positions don't change on BOSS > instrument GUI while they actually work properly. Shutter opens when it should. > > 10. Some scripts don't work anymore because SP2 is removed. Some need some > cleans. Dylan and Dmitry will work on them. > > > > > ---- Observing Log ---- > > Focus B1 and R1: > 21:00Z: started to take bias and dark to see if the data look fine although r1 > was still cooling down. The data look fine. > 21:40Z:Cameras are cold enough to start focusing the cameras.Started the process. > During focus sweep, we need to move spectrograph collimator +12K steps in both > direction from the best focus position. Therefore, we would like to focus cameras > with boss the collimator close to the middle of its moveable range. We could not > do so. I had to set the red camera focus ring at its farthest edge in positive > direction in order to make just enough room for the focus sweep. If temperature > drop more, we would not have enough collimator move range for the focus sweep > data.I think that we need a thicker shim. > > With flats, we measured camera rotation angle to have fiber images be perfectly > verticle. The measurements shows that b1 camera needs to rotate 0.01 deg > clockwise, R1 needs to rotate 0.15 deg counter clockwise. Both cameras are > within the tolerance of 0.5 deg, so we didn't rotate cameras. > > Hector and Jose had to make several corrections in the codes of SOS pipeline > before it finally deliveries the correction results. e.g. getting correct > plate type in the fits header, having the correct slithead info in the SOS > code. We checked and found the slithead on cart 1 is from SP2 on cartridge 11. > We need to collect the info for all converted cartridge and send to Hector. > SOS still doesn't reduce new data automatically, had to re-reduce. I used > the command: sos_aporedo -m 59139 -z 318265 -g. Hector fixed the problem later. > Data taken for the focus sweep are reduced automatically. > > We had trouble to connect to gcameraICC. We tried to reset cables on both side, > powered cycle the camera and the Magnum switch, used different ethernet cable, > none of these work. ping cannot reach the device. > ping 25m-guide-camera.apo.nmsu.edu > PING 25m-guide-camera.apo.nmsu.edu (10.25.1.70) 56(84) bytes of data. > From sdss4-hub.apo.nmsu.edu (10.25.1.1) icmp_seq=2 Destination Host Unreachable. > > 08:11Z: collimate the spectrograph. > 08:08:01 boss exposure 4.0, file=318262 > 08:09:07 boss Idle > 08:09:15 boss exposure 4.0, file=318263 > 08:10:20 boss Idle > 08:11:07 Hartmann collimate output on cart #1 > Hartmann failed > sp1: offset: r= 1649 (Out of focus); b= -6.2 (Out of focus) > sp1: pred. move: spAverageMove= 1820 > sp1: pred. resid: r= -171, b= -0.5, txt= OK, spTemp = 999.9 > > flat and arc: 318264-65. > XMIDs are ok. Adjust WaveMid by -7A on b1 and -10A on r1. > "boss boss moveColl spec=sp1" failed because of unknown position. But the > collimator actually moved. > Recollimate spectrograph. frame numbers: 318276-277 > sp1: pred. resid: r= -49, b= -0.2, txt= OK > > flat and arc: 318278 - 279 > boss moveColl spec=sp1 a=7500 b=7500 c=7500 > 09:28:59 OBSERVER.kpan 218 boss i text="motors at [24682, 25210, 24955]" > the command failed due to unknown motor position, while it seems have the > position, and collimator moved because images indicate focus changes. > sop hartmann fr: 318280-281 > mcp ff.on > boss exposure flat itime=25 fr: 318282 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318283 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at [23182, 23710, 23456] > sop hartmann fr: 318284-285 > mcp ff.on > boss exposure flat itime=25 fr: 318286 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318287 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at [21682, 22210, 21957] > sop hartmann fr: 318288-289 > mcp ff.on > boss exposure flat itime=25 fr: 318290 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318291 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at [20182, 20710, 20458] > sop hartmann fr: 318292-293 > mcp ff.on > boss exposure flat itime=25 fr: 318294 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318295 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at motors at [18682, 19210, 18958] > sop hartmann fr: 318296-297 > mcp ff.on > boss exposure flat itime=25 fr: 318298 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318299 > mcp hgcd.off > mcp ne.off > > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at motors at [17182, 17711, 17459] > sop hartmann fr: 318300-301 > mcp ff.on > boss exposure flat itime=25 fr: 318302 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318303 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at motors at [15682, 16211, 15961 > sop hartmann fr: 318304-305 > mcp ff.on > boss exposure flat itime=25 fr: 318306 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318307 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at motors at [14182, 14711, 14463] > sop hartmann fr: 318308-309 > mcp ff.on > boss exposure flat itime=25 fr: 318310 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318311 > mcp hgcd.off > mcp ne.off > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at motors at [12681, 13211, 12964] > sop hartmann fr: 318312-313 > mcp ff.on > boss exposure flat itime=25 fr: 318314 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318315 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at motors at [11181, 11711, 11463] > sop hartmann fr: 318316-317 > mcp ff.on > boss exposure flat itime=25 fr: 318318 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318319 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=-1500 b=-1500 c=-1500 > motors at motors at [9681, 10211, 9961] > sop hartmann fr: 318320-321 > mcp ff.on > boss exposure flat itime=25 fr: 318322 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318323 > mcp hgcd.off > mcp ne.off > > boss moveColl spec=sp1 a=7500 b=7500 c=7500 > motors at motors at [17182, 17710, 17461] > sop hartmann fr: 318324-325 > mcp ff.on > boss exposure flat itime=25 fr: 318326 > mcp ff.off > mcp hgcd.on > mcp ne.on > boss exposure arc itime=4 fr: 318327 > mcp hgcd.off > mcp ne.off > > flat, arc: 318328-329. > > sop collimateBOSS: frames: 318330-331. > sp1: pred. move: spAverageMove= -618 > motors at [16564, 17092, 16835] > sp1: pred. resid: r= -40, b= -0.1, txt= OK, spTemp = 999.9 > flat and arc: 318332-318333. > 12:15Z: call it the night. Forced fill the 10L dewar. Started 20 biases and 10 > darks. > > > > ____________________________________________________________ > Logs of Nightly APO Activities > https://trac.sdss.org/tracmailman/browser/private/sloan-25mlog/index.html