Subject: Re: [sloan-25mlog 4099] Re: 2.5m obslog 20180525 (SJD 58264) From: Kaike Pan Date: Sat, 26 May 2018 16:16:39 -0600 > On May 26, 2018, at 3:01 PM, Daniel Oravetz = wrote: >=20 > Hi Kaike, >=20 >>> We also found a SOP bug. When modifying an Apogee Manga sequence it >>> seems SOP >>> can only display so many Cs. For example, when starting a default >>> sequence SOP >>> will show Cccc and then move to cCcc once the next exposure starts. = We >>> tried to >>> modify the sequence by adding 1 count of CC during the last = exposure. >>> SOP goes >>> from cccC to ccCcc. This fails to show one completed c on the left. >>> After that >>> 4th exposure finishes SOP shows ccccC, omitting the final c on the >>> right. Here >>> the display is worrying because us observers don't know if another >>> exposure will >>> be taken. But another exposure does start without our intervention = and >>> SOP then >>> displays ccccc, missing the C at the end. It seems that SOP can only >>> show 5 Cs >>> at once, but that that modifying does work correctly. All Apogee As = and >>> Bs >>> executed correctly. >>=20 >> Yes. modification on apogee and MaNGA sequence works differently from >> eBOSS plate. This is how it works (I think that we a page in = observing >> tips page on this). Basically, modification will not show completed >> exposures, it shows only on-going one and ones plan to take. >=20 > You might have misunderstood the description. The problem was not with = the > modification of the sequence (the modified sequence actually completed > appropriately) it was a problem with the sequence+progress display for = 'Do > Apogee Mange Sequence' within SOP GUI (the sequence+progress display = did > not agree with where we were actually at in the modified sequence). >=20 > The modification of count+dithers did, in fact, update the dither = sequence > from the current observed dither at the time, which is what it's = supposed > to do and in agreement with the note you're referring to on the = Observing > Tips page. However, as Gordon noted in the log, the sequence+progress > display for 'Do Apogee Manga Sequence' did not display correctly after = the > modification, either backward in time (it didn't display an > already-completed 'c'), or forward in time (it did not display the = last > in-progress exposure 'C'). >=20 > I wonder if this misbehavior was somehow triggered by the plate having > been a 'DAB' plate? I don't remember having problems with the > sequence+progress display for 'non-DAB' plates and I certainly know = that > 'Do Apogee Manga Sequence' displays more than five characters for the > sequence+progress display for MaNGA-led observing and it does so = correctly > after modification as well. >=20 > Dan >=20 Yes, SOP can show more than five characters. I think that it might be = due to that it=E2=80=99s a =E2=80=98DAB=E2=80=99 plate and modification was done during the last =E2=80=98C=E2=80=99 of = in-progressing one =E2=80=98cc=E2=80=99 count. We can investigate more = and file=20 a ticket if needed. Thanks,