Subject: Re: [sloan-25mlog 4088] Re: 2.5m obslog 20180520 (SJD 58259) From: Kaike Pan Date: Mon, 21 May 2018 08:58:58 -0600 Yes. What I mean is that If we know it will stop at the same place, no = point to try more times, and we just need to be care to proceed with the = telescope at 5.5 deg.=20 > On May 21, 2018, at 8:54 AM, John Downey wrote: >=20 > The telescope would not go to 5 degrees because the flat field petals = could not be fully closed. Since there was no real harm in trying a = couple times I didn't make a point of trying to break in to explain why = it was stopping where it was. It does no harm to try a couple times if = you like, but there is not much point to it, the PLC usually stops the = telescope where it does for a reason, only rarely is it due to a fault. >=20 >> On May 21, 2018, at 7:31 AM, Kaike Pan wrote: >>=20 >> Totally understand. I mentioned the information, because observers = attempted to have the telescope goto the 5 degrees several times (and = didn=E2=80=99t get there). In such cases, we can excise the procedure = (with the ladder) after two attempts or so. >>=20 >>> On May 21, 2018, at 8:19 AM, John Downey = wrote: >>>=20 >>> Given what Dmitry reported concerning clearance, any time the = enclosure bypass is used I would like a person on a ladder as they did = last night to be absolutely sure there will be no collision with the = building. While the enclosure may clear at 6 degrees with the door = fully open, please remember that the enclosure bypass also bypasses the = door position switch, so there is nothing to stop the enclosure from = moving with the door down an extra 6 inches and the telescope at 5.5 = degrees. This is why the interlock was changed from 6 degrees to 5, for = a margin of safety. >>>=20 >>> With two observers available for emergency closing, it is really not = difficult to exercise some sensible precautions like this one. >>>=20 >>> John >>>=20 >>>> On May 21, 2018, at 7:11 AM, Kaike Pan wrote: >>>>=20 >>>> Thank you for being caution. Just for information, we should be = able to open/close with the telescope at 6 degree. We did that for a = short period of time after the modification of the FFS motor system, = decided to change to 5 degree to give more clear space. >>>>=20 >>>>> On May 21, 2018, at 5:05 AM, dmbiz@apo.nmsu.edu wrote: >>>>>=20 >>>>>=20 >>>>> APACHE POINT OBSERVATORY SDSS 2.5M >>>>>=20 >>>>> OBSERVING LOG >>>>> Sunday May 20, 2018 >>>>>=20 >>>>> (SJD 58259) >>>>>=20 >>>>> ---- Observing Team ---- >>>>>=20 >>>>> Karen Kinemuchi >>>>> Dmitry Bizyaev >>>>>=20 >>>>> John Downey (over the phone) >>>>>=20 >>>>> ---- Observing Plan ---- >>>>>=20 >>>>> Sun 20 MAY 2018 58259.0 0.34 03:19 10:42 12:10 19:35 = ---- =20 >>>>> MaNGA until 08:07 ( 4.8 h), then eBOSS ( 2.6 h)=20 >>>>>=20 >>>>> ---- Observing Summary ---- >>>>>=20 >>>>> Clear night with high humidity in the first part.=20 >>>>> FFS hardware problem stopped observations early.=20 >>>>>=20 >>>>>=20 >>>>> eBOSS >>>>> ----- >>>>> 17 10925 eBOSS 3x900s not finished >>>>>=20 >>>>>=20 >>>>> Notes: >>>>> * 1-m port: 2:30Z - 10:53Z >>>>> * dust accumulated: ~4000 >>>>> * Serious problem with FFS power supply, see log. In combination = with=20 >>>>> high humidity, we lost 3h51m to the FFS problem, and 3h29m to=20 >>>>> bad weather. >>>>> By-survey break down is tricky, since we had to observe eBOSS = plates >>>>> during official MANGA time, and MANGA plates during eBOSS time = because of the=20 >>>>> gaps in plates for both surveys. Based on the actual *ability* to = observe, >>>>> we propose to count that eBOSS lost 2h 47 min to the weather (from=20= >>>>> stopping to the end of cart 13). MANGA lost 42 min to weather, and = 3h11m >>>>> to the hardware problem. APOGEE lost 40m of time between the = 15-deg and 8-deg >>>>> twilight to the hardware problem.=20 >>>>>=20 >>>>> * Attention to JohnB/IT: the weather page for the 2.5m showed ~50% = humidity >>>>> all night long, dropping sharply from ~80% to this value within a = few minutes. =20 >>>>> At the same time, the 3.5m part suggested very high humidity, the = enclosure=20 >>>>> doors were damp, and the reader inside the 2.5m enclosure showed = close to 100%=20 >>>>> value. Please check if the humidity sensor behaves.=20 >>>>>=20 >>>>> ---- Observing Log ---- >>>>>=20 >>>>=20 >>>> ____________________________________________________________ >>>> Logs of Nightly APO Activities >>>> = https://trac.sdss.org/tracmailman/browser/private/sloan-25mlog/index.html >>>=20 >>=20 >=20