Subject: Re: [sloan-25mlog 3874] Re: 2.5m obslog 20180205 (SJD 58155) From: John Downey Date: Tue, 6 Feb 2018 15:15:11 -0700 > On Feb 6, 2018, at 2:55 PM, Dmitry Bizyaev wrote: >=20 >>> FFS interlocks bypassed >>=20 >> They are not bypassed. Three of the petals are running on the = controllers for >=20 > John, > we have to set Bypass in SOP (in STUI) to make guider > working if not all petals are reported as completely open. Oh, I see now, though that is not an interlock, at least not in the = sense that the term is typically used around mechanical systems. I thought it was a reference to the PLC preventing petal operation under = certain circumstances such as when the building is on or the ALT is too = low. >=20 > Dmitry >=20 >=20