Date: Thu, 23 Mar 2017 11:33:14 -0600 (MDT) Subject: Re: [sloan-25mlog 3428] Re: 2.5m obslog 20170322 (SJD 57835) From: "Audrey Oravetz" https://trac.sdss.org/ticket/2705 > Do we have a ticket filed on this? > > --Connie > > On Thu, Mar 23, 2017 at 6:29 AM, Kaike Pan wrote: > >> >> > -- first hartmann on cart 6 got "sp2 piston=0" & "Failed to move >> collimator >> > pistons for sp2.". Karen did 'boss reload controller' and repeated >> collimations. >> > No lost time. >> > >> >> For information, this is a bug in hartmann code: if requested collimator >> move is zero, >> harthmann will fail (which results gotoFeild failure). Nothing is wrong, >> we just need >> to take a set of calibration, and start guider. Or one can unselect >> hartmann and >> re-gotoField (if you do so, please check hartmann back after the >> gotoField >> completed, >> otherwise, no hartmann will be taken —> BOSS will not be collimated in >> later plates). >> >> -kaike >> >> ____________________________________________________________ >> Logs of Nightly APO Activities >> https://trac.sdss.org/tracmailman/browser/private/sloan-25mlog/index.html > ____________________________________________________________ > Logs of Nightly APO Activities > https://trac.sdss.org/tracmailman/browser/private/sloan-25mlog/index.html