Subject: Re: [sloan-25mlog 3798] 2.5m obslog 20171214 (SJD 58102) From: John Downey Date: Fri, 15 Dec 2017 09:39:05 -0700 >=20 > Notes > =3D =3D =3D > 1. Scissors lift tripped the circuit breaker #26 on the first cart = change. > Reseted. No time lost. > After the reset it doesn't work properly: it moves ~ 5 sec, then = stops, > irrelevant to the standard loading positions. > It is doable to operate it, but please check in the day time. >=20 >=20 > -- > During the cart change the scissors lift got stuck in the middle of = moving. > Motor was working on a very uneven way, mumbling, stopping and = starting. In a > few seconds it stopped. We've found that the mirrors are not relevant, = nd found > a tripped breaker (#28) for the lift. Reseted the breaker, the problem > disappeared. After that the list started moving smoothly. No time lost = for this > problem.=20 We've not been able to repeat the problem this morning. I don't think we can conclude that the mirrors were not relevant in this = case, as in all other respects this sounds like a light curtain problem. = Although it is a mystery why the problem disappeared after tripping and = resetting the breaker, I suspect that is coincidence. We are working on plastic mirror mounts that should remove the = temperature dependence of the light curtain if anything can. I am = hoping to have them installed during January engineering time. If that = does not correct these ongoing problems, I believe we will have to have = an infrastructure discussion concerning the light curtain, whether we = need it, what other options exist, and how long we need to maintain it = (SDSS5 need to be in that discussion as well).=