Subject: Re: [sloan-25mlog 3341] 2.5m obslog 20170126 (SJD 57780) From: John Downey Date: Fri, 27 Jan 2017 07:59:01 -0700 Sorry about the mis-sent reply just now, hit the wrong button >=20 > At the morning before we close telescope:=20 > -- The manipulator arm worked not properly, sporadically stopped = during motion > by track. > -- The lift in cartridge bay also moving down with sporadically = stopped. >=20 This is the light curtain, again. There was no work done in the bay = yesterday (there had been the last time we saw a light curtain problem), = so it's likely temperature related. We'll check today and adjust as needed.=