Subject: Re: [sloan-25mlog 1952] 2.5m obslog 20141028 (SJD 56959) From: Dan Long Date: Wed, 29 Oct 2014 08:31:11 -0600 Hi Patrick and Howard, Remember that until the software is updated, that you need to issue = an axis stop between the time you reach instrument change and when you = release the stop button and initialize the telescope to move again. =20 This will prevent any accumulated error in axis position from being = applied to the servo loop on initialization and potentially triggering = oscillations. Cheers, Dan On Oct 29, 2014, at 6:49 AM, pgaulme@apo.nmsu.edu wrote: >=20 > APACHE POINT OBSERVATORY SDSS 2.5M >=20 > OBSERVING LOG > Tuesday October 28, 2014 >=20 > (SJD 56959) >=20 > ---- Observing Team ---- >=20 > Howard J. Brewington > Patrick Gaulme >=20 >=20 . . . > 2) When going from instrument change to stow (before going to 5 to = close the=20 > enclosure), the rotator started to oscillate. We tcc axis stop than = pushed the=20 > stop button. We started over with releasing the stop button, tcc axis = init, and=20 > stow, and that solved the problem.=20 >=20