Subject: Re: [sdss3-25mlog 1471] 2.5m obslog 20131108 (MJD 56605) From: Dan Long Date: Sat, 9 Nov 2013 06:16:30 -0700 Hi Audrey and Garrett, The imager loop no longer exists. The temperature sensors are still = in the system since a disconnected sensor will affect the measurements = of other sensors in the bank. The imager loop sensors are in the cable = tray above the hanging racks. The cartridge cover latches will be checked/tightened as they are = encountered in plugging (the rest on Monday), and the mounting bolt for = 16 will be replaced as soon the proper part is located. Cheers, Dan On Nov 9, 2013, at 5:31 AM, asimmons@apo.nmsu.edu wrote: >=20 > APACHE POINT OBSERVATORY SDSS 2.5M >=20 > OBSERVING LOG > Friday November 08, 2013 >=20 > (MJD 56605) >=20 > ---- Observing Team ---- >=20 > Garrett Ebelke > Audrey Oravetz > Dan Long (support) >=20 >=20 . . . > In response to yesterdays Day Log re: TEC Chiller Pump - Not sure if = this is=20 > related or not, but after sending out the night log last night we = noticed that=20 > in the TPM Temperature Graphics Truss window, the "Imager Glycol = Supply"=20 > temperature is roughly +4-5deg above ambient, while the "Imager Glycol = Return"=20 > is roughly +2-3deg above ambient. This doesn't quite make sense. If = you follow=20 > the logic of a coolant system, the supply should be cooler than the = return=20 > (since the return is coming back after removing heat from various = systems). With=20 > this thinking and looking at the other loop, the "Spectro Glycol = Supply" is=20 > roughly +0-1deg above ambient, while the "Spectro Glycol Return" is = roughly +2- > 3deg above ambient, which seems reasonable. After speaking with JonB = about this=20 > in passing, he brought up the question if the Imager Glycol Return = line actually=20 > does anything now or if those sensors are obsolete. >=20 > We've noticed that quite a few of the slithead cover latch mechanisms = are coming=20 > loose. The "stake" piece of the clamp that is attached to the = cartridge by 2=20 > small bolts is loosening up due to the bolts coming loose. Please = check them and=20 > add loctite as needed. >=20 > Cartridge 16 - When inspecting the cartridge bay in the evening, we = discovered=20 > that the kinematic mounting block facing North (while cart is in the = bay) is=20 > missing one of the four mounting bolts. If I recall correctly, these = mounting=20 > blocks are mounted with the 4 bolts and 2 alignment pins, so as long = as the=20 > other 3 bolts are tightened down, it should still be safe to mount. We = have=20 > contacted Dan Long to verify this thinking. >=20 >=20 > _____________________________________________________ > Message 1471 of sdss3-25mlog - Logs of nightly APO activities. > = https://trac.sdss3.org/tracmailman/browser/private/sdss3-25mlog/all/1471.h= tml > sdss3-25mlog@sdss3.org > https://sdss3.org/mailman/listinfo/sdss3-25mlog