Date: Mon, 12 Nov 2012 09:23:14 -0700 (MST) From: Matt Olmstead Subject: Re: [sdss3-25mlog 917] 2.5m obslog 20121111 (MJD 56243) Hi Kaike, After a very quick look, it appears to be the case where we are just inside the tolerance (b2 -0.2 pixels and r2 0.2 pixels out of focus) so passes the collimate criteria (otherwise would need to move the rotator ring) and is just barely not making the xsigma requirement. I believe the xsigma threshold was set fairly tight so these should be fine since very close to threshold. I will look at a few more things later today to make sure this is correct. Thanks Matt On Mon, 12 Nov 2012, Kaike Pan wrote: > > On Nov 12, 2012, at 5:42 AM, kinemuchi@apo.nmsu.edu wrote: > >> >> APACHE POINT OBSERVATORY SDSS 2.5M >> >> OBSERVING LOG >> Sunday November 11, 2012 >> >> (MJD 56243) >> >> ---- Observing Team ---- >> >> Viktor Malanushenko >> Karen Kinemuchi >> >> Elena Malanushenko (Afternoon preparation) >> >> ---- Observing Plan ---- >> >> 11 Nov 2012 56243.0 0.13 01:14 12:21 21:37 08:46 BOSS 11.1 hours >> >> >> ---- Observing Summary ---- >> >> BOSS observing: >> >> Cart 10 (Plate 5040) -- COMPLETE! >> Cart 11 (Plate 5046) -- COMPLETE! >> Cart 13 (Plate 6174) -- COMPLETE! >> Cart 15 (Plate 6279) -- COMPLETE! >> Cart 14 (Plate 6273) -- COMPLETE! >> Cart 16 (Plate 6377) -- COMPLETE! (S/N)^2 was met (red > 44, blue > 20) > Observing plan is updated accordingly. > >> Cart 18 (Plate 5767) -- not complete >> >> With the cold temperatures (-5 degrees), we did not have much trouble with >> finding guide stars. The first cartridge had an RA=10" and DEC=20" offset, but >> the subsequent cartridges had smaller offsets. The pointing model seems to be okay. >> NOTE TO DAY STAFF: >> >> The scissor lift worked fine during afternoon checkout, but during the night, it >> would not move. We called Kaike and DanL, and the solution was to run the >> scissor lift manually from inside the plug lab. DanL suggested that the mirrors >> might be slightly misaligned (we could see no obstructions to the mirror >> pathways), so this will be fixed in the morning. NO LOSS TO BOSS SCIENCE TIME. > > Thanks Karen and Viktor for the effort. > >> >> MINOR HICCUPS: >> LN2 tank near SP1 seemed to be under pressure and the weight would be "red" on >> the TPM display. RESOLVED: There was still a little LN in the hose, so we >> vented and opened the hose (with the tank valve closed). The warning went away, >> however we suspect there may be a small leak? >> >> ODH alarm by the LN2 shed next to the plug lab went off around 03:35Z but as the >> cold observer approached it, the alarm shut off by itself. The day staff should >> check to make sure everything is okay there please. >> >> The b2 flat field (file 150617) for Plate 6273 (Cart 14) had the XSIGMA >> parameter out of spec (appears in red on the SOS webpage). We examined the >> previous flat field and found no major differences. We examined the science >> data taken directly after the flat and did not see any problems. Please see >> more discussion in the Log and in "Problems in Detail". >> Happened again for Cart 16 (Plate 6377) for the b2 camera. >> > > Kyle and Matt, XSIGMA on b2 on cart 14 and 16 are red. On both plates, S/N on > b2 are actually better than b1, and collimation shows spectrograph was in focus. > Could you please take a look on it? Thanks, >