Subject: Re: 2.5m obslog 20100515 (MJD 55332) From: Russell Owen Date: Sun, 16 May 2010 12:30:29 -0700 On May 16, 2010, at 4:22 AM, Kaike Pan wrote: > All actors were checked amd confirmed alive. However, we saw a pink = question=20 > mark next to "guiding" on guider GUI window. According to Paul, guider=20= > v1_0_20ee version has been setup and running. But according to STUI = (guider=20 > ping), v1_0_20e, instead of v1_0_20ee, is running. According to eups, = v1_0_20e=20 > is current, v1_0_20ee is test. We sent paul a email on this. The pink question mark almost certainly means that the guider is not = outputting status when the hub first connects to it, or rather that the = hub is not soliciting the status. I've reported this as ticket #841. For STUI to output proper status reliably when it connects, it is = essential that the hub learn all the status from each actor as it = connects to that actor (either by explicitly sending appropriate = commands to the actor, or by the actor automatically outputting that = information when a client connects). -- Russell