From: kaike pan Subject: Re: [SDSS3-infrastructure 1889] Re: 2.5m obslog 20091104 (MJD 55140) Date: Thu, 5 Nov 2009 14:54:17 -0700 Yes, right now. There are so many info scrolls by the log window. Some times, it is hard to catch all info. I second Steph's point, it would be much nicer if we can have the info in a static place in the GUI. I guess for loadCartridge command, the info we need is: plateid, cartridgeID, coordinates of the field, and which fibers are automatically enabled Show only true ones are enough (assumed all other fibers are disabled), like: gprobes="(2=True)","(4=True)","(6=True)",,"(8=true)","(10=true)" -kaike On Nov 5, 2009, at 12:32 PM, stephanie snedden wrote: > I think the problem is that the info scrolls by so fast that some > people never really realized it was there. Once this info is in a > static place in the GUI, life will be better. > > Steph > On Nov 5, 2009, at 12:18 PM, paul harding wrote: > >> Kaike, >> The guider loadCartridge command has always shown the enabled fibers. >> I would include the example of what is reported in the log window but >> platedb appears not to be working at present. >> >> 19:16:32 8 guider loadCartridge cartridge=4 >> 19:16:32 .sop 0 sop d text="boss alive" >> 19:16:32 .hub 0 cmds d CmdIn="APO.harding","guider","loadCartridge >> cartridge=4" >> 19:16:32 .hub 0 cmds d >> CmdQueued=311133,1257448626.31,"APO.harding",8,"guider", >> 35,"loadCartridge cartridge=4" >> 19:16:32 .hub 0 cmds d >> CmdIn="APO.harding.guider","platedb","loadCartridge cartridge=4 >> pointing=A" >> 19:16:32 .hub 0 cmds d >> CmdQueued=311134,1257448626.38,"APO.harding.guider",640,"platedb", >> 541,"loadCartridge cartridge=4 pointing=A" >> 19:16:32 APO.harding.guider 640 platedb f text="command failed: >> InvalidRequestError(\"Can't reconnect until invalid transaction is >> rolled back\",) at /home/sdss3/products/Linux64/sqlalchemy/0.5.5/ >> lib/python/sqlalchemy/engine/base.py:576" >> 19:16:32 .hub 0 cmds d CmdDone=311134 >> 19:16:32 APO.harding 8 guider f text="Failed to lookup plate >> corresponding to 4/A" >> >> Paul >> >> >> On Nov 5, 2009, at 12:22 PM, kaike pan wrote: >> >>> Hi Robert and Paul, >>> >>> Is it possible for loadingCartridge command to show which guiding >>> fibers are >>> enable? I think this will be useful to us (yes, guider status can >>> give us >>> the info. But we don't have to use the command for the info if >>> loadingCartridge >>> does so, because loadCartridge is a "must" step for an observation). >>> >>> -kaike >>> >>> >>> >>> On Nov 5, 2009, at 10:01 AM, paul harding wrote: >>> >>>> I think this is a case of history becoming precedent. >>>> >>>> In the past marvels plates were mostly designed with >>>> pointing A with even guide fiber numbers >>>> pointing B with odd guide fibers numbers >>>> >>>> While this was convenient for the operators it was never meant >>>> to be a rule. >>>> There is no reason why any plate pointing could not have any >>>> subset of guide fibers assigned. >>>> The odd even assignment is not possible on preselection plates, >>>> nor will it be possible when the >>>> marvels cartridges are upgraded in the future with new guide >>>> fibers. >>>> >>>> As RHL says the guider loadCartridge command shows which guide >>>> fibers are assigned to guide stars >>>> for that pointing and thus enabled. Observers should note which >>>> fibers are initially enabled when loading a cartridge. >>>> >>>> The guider status command shows the current state of enabled and >>>> disabled fibers, it reflects the changes >>>> applied by the operators with the enable and disable commands to >>>> the original state when the cartridge was loaded. >>>> >>>> Fibers that are disabled when the cartridge is loaded should not >>>> be enabled. >>>> >>>> Paul >>>> >>>> >>>> >>>> On Nov 5, 2009, at 11:09 AM, Robert Lupton the Good wrote: >>>> >>>>>> Another piece of info. According to plate design >>>>>> team, that odd fibers for A pointing, even for B pointing >>>>>> will not apply for newest designed plates. >>>>> >>>>> The code doesn't use Even/Odd, it looks in the plPlugMap file >>>>> to see which guide fibres are in use. At least, I think it >>>>> does. The loadCartridge command will report which fibres are >>>>> enabled. >>>>> >>>>> R >>>>> >>>>> >>>>> DSS DSS DSS DSS DSS Digital Sky Survey DSS DSS DSS DSS DSS DSS >>>>> DSS *** The information posted to SDSS mailing lists is >>>>> proprietary *** >>>>> DSS This is message 4859 in the sdss-25mlog archive, URL >>>>> DSS http://www.astro.princeton.edu:81/sdss-25mlog/msg. >>>>> 4859.html >>>>> DSS The index is at http://www.astro.princeton.edu:81/ >>>>> sdss-25mlog/INDEX.html >>>>> DSS To join/leave the list, go to >>>>> DSS http://www.astro.princeton.edu:81/cgi-bin/ >>>>> mailinglists.pl/show_subscription?list=sdss-25mlog >>>>> DSS To post a message, mail it to sdss-25mlog@astro.princeton.edu >>>>> DSS >>>>> DSS DSS DSS DSS DSS DSS DSS DSS DSS DSS DSS DSS DSS DSS DSS DSS >>>> >> >> _______________________________________________ >> Message 1889 of sdss3-infrastructure - >> sdss3-infrastructure@sdss3.org >> https://sdss3.org/mailman/listinfo/sdss3-infrastructure > >