From: stephanie snedden Subject: Re: 2.5m obslog 20070512 (MJD 54233) Date: Sun, 13 May 2007 11:50:42 -0600 Curious. The only clue I found was that when you were acquiring the field, it was transiting, although only at an alt of about 75 degrees. Still, that might be a factor in why you were losing guide stars (high rot rate) Another factor may have been poor seeing? Some things to try: - Do the scale change in small steps (don't move the mirrors too much at one time) to help avoid losing stars - Keep your guider exposure times short (10 sec) and let the stars recenter before doing the next scale change. - Keep an eye on the size of the rotator errors/corrections. Steph On May 13, 2007, at 6:25 AM, doravetz@apo.nmsu.edu wrote: > > Cartridge 3, plate 2599, chunk153, Legacy. > Guide stars found on gotoField after using an offset (guide star in > fiber 5 > was seen glowing just outside of the fiber's edge). The Guider > Data Window > was asking for percent scale change 0.024 and we could not adjust > the scale > without losing guide stars. We made several attempts and finally > we skipped > this cartridge. Details of the situation are described below. > > 04:23Z - Guide stars found on gotoField after using an offset > (guide star in > fiber 5 was seen glowing just outside of the fiber's edge). After > a scale > change and focus adjustment only 2 guide stars were present, so > another > gotoField was used in attempt to reacquire the field. Only 2 guide > stars were > found again, so we cleared the offsets and issued another > gotoField. No guide > stars were found, so then we tried an fk5 and couldn't locate it > either. > Finally, we set the scale back to 1.000000 and then tried an fk5. > Now the fk5 > star is seen in fiber 10, so we centered it and stickied the > offsets and > issued gotoField again. No guide stars were seen. We went back to > the fk5 > and stickied the offsets again (just to make sure). This time > guide stars > were found on gotoField. When we adjusted the scale according to > the percent > scale values given in the Guider Data Window, we lost guide stars, > and the > percent scale values increased. For instance, it was asking for a > scale > change of 0.024, so we applied 0.01 and then it asked for 0.04. > Our several > attempts to change the scale resulted in scale values subsequently > larger and > guide stars lost. Perhaps Cartridge 3 needs to be checked? We > moved to > Cartridge 4 to see if we experienced similar behavior and we did not.