Date: Tue, 20 Apr 2004 21:07:09 -0400 (EDT) From: David Schlegel Subject: Re: Spectro focus once again [was RE: 2.5m obslog 20040419 (MJD Pete, As per spectro collimation procedures: I would suggest we go with the procedures as suggested some time ago, e.g. sdss-obs/3743 That basically says that we try to start each plate "in the black" for XSIGMA/WSIGMA, and then there should never be any loss of data. The lost time that we've had has always been when plates are started with the spectrographs just "on the edge" of being inside specs. My guess as to the numbers are something like: |COLLIMATE offset| 0.7 pix : In the red according to SOS (The above numbers could be measured, but I don't think ever have; the guesses above are made from just taking some quadrature differences.) Thus, if you collimate and put the shifts all within 0.15 pix (esp. at zenith), then it's very much in collimation. Moving the telescope around is at worst a 0.2 pix shift peak-to-peak (cf. sdss-obs/3618 and refs), which isn't a big deal. Temperature shifts are probably the biggest culprit for changing things. If we knew the shifts w.r.t. temperature, one could also pro-actively change collimation at the beginning of each plate. But even if that we done, we should *still* have the procedures as stated above. Didn't someone look at the temp shifts at some point -- I can't seem to dig that up. -David