Date: Tue, 25 Mar 2003 09:09:43 -0500 (EST) From: jegunn Subject: RE: 2.5m obslog 20030324 (MJD 52723) I ran some raytraces a few months ago with the corrector decentered and tilted, and there is no way that it can cause these problems. I am pretty sure I posted those results. So we need to find another culprit. I am (still) betting on the seating of the cartridges in the kinematics. --jim On Tue, 25 Mar 2003, Pete Newman wrote: > > Thanks, Pete. Our luck has been so lousy this run that it seemed unlikely; > > I was going to suggest a pointing model, but three out of four success > > is not bad. Now all we need to do is understand what went wrong last > > night..... > > We certainly do. The pointing while imaging 28N on 52722 was spot on, but > we had all that fun with spectroscopy, e.g. cartridge 7 needed an FK5 and > then had a weird offset back at the field. Last night (52723), same > cartridge, same plate, we got guide stars right away. > > I _did_ unmount and remount the corrector this afternoon so show Jon B some > lateral motion in the turtle cart interface to the rails, but I don't > believe the corrector itself did anything but seat perfectly. Don't believe > it yet, anyway. > > I'm running out of head to scratch! > > --Pete (about to retire for the day) > >