Date: Mon, 23 Apr 2001 09:47:25 -0700 From: Russell E Owen Subject: Re: 2.5m obslog 20010422 (MJD 52022) At 5:44 AM -0600 2001/04/23, Pete Newman wrote: >Problem 5. > >0 10 > Started; Cmd='offset object >-5.6474308490244936e-06,-4.4217200943637069e-05' >0 10 I MoveItems="NNNYNNNNN"; Moved >0 10 I ObjOff = -0.001915, 0.000000, 4494725685.06000, -0.001115, >0.000000, 4494725685.06000 >0 10 : >0 10 > Started; Cmd='offset rotator -8.4557439247492122e-05' >0 0 F Modu="prt_Read"; Text="read timed out on port LTA19:" >0 0 F Modu="axe_o_Move"; Text="command failed for ROT" Thanks for the helpful problem report. I agree that this looks like the earlier errors. The TCC tracking process timed out waiting for an axis controller reply, and so initialized everything. I also worry about the command "offset rotator -8.4557439247492122e-05". Due to limitations in the TCC command interpreter, exponential notation does *not* work reliably and should never be used. I have filed a PR. I'll look through the logs and report on timeouts on LTA19 and slowdown errors. -- Russell