Date: Sat, 15 May 1999 06:41:46 -0600 From: long@apo.nmsu.edu (Dan Long) Subject: 2.5m obslog 990514 ( MJD 51313 ) FRIDAY MAY 14, 1999 APACHE POINT OBSERVATORY SDSS 2.5m OBSERVING LOG Tonight we saw that the recollimation of the secondary did wonders for the image quality. Images looked round rather than triangular. We had less success when it came to tracking. There were rotator oscillations at a large number of angles. We will need the rotary encoder back for Saturday night's operation. The imager was on all night tonight. There were plans to put the cartridge on during second half, but when rotator oscillations were discovered, tracking was no longer an option, so we parked on the equator and continued imaging. There was trouble with alt fiducials not working at the start of the night. It turns out someone had unplugged the reader for some reason, and forgotten to put it back. First we set up on the equator. Images look much nicer now. There is only a small amount of coma. All other image artifacts are gone. The rate was checked on the equator. We then set up on on a great circle ahead of M13. Slew command below. track 247.925,35.544 fk5 /rotty=obj /rota=-.22 /scanvel=(.002759,.003138) Robert wrote a proc to take the rotation info and apply it via a series of small calibration offsets in two second intervals. The TCC was decidedly unhappy with this. Below is the TCC output after a series of calibration offsets in rotation. About 7 of them in .03 deg increments. 0 2 I CalibOff = 0.000000, 0.000000, 4433471672.38000, 0.000000, 0.000000, 4433471672.38000, -0.0300 00, 0.000000, 4433471672.38000 0 2 : 0 0 ! Facil="SYSTEM"; VMSMsg="HPARITH"; EText="high performance arithmetic trap, Imask=00000000, Fma sk=00002000, summary=04, PC=000D17A0, PS=0000001B" 0 0 F DeadProc="T_TRACK" 0 0 W Modu="axe_i_Stop"; Text="no axes specified; nothing done" 0 0 F Modu="axe_i_SchMove"; Text="tracking failed; axes halted" 0 0 I AxisStop="TTT" 0 3 F Text="move failed; axes halted" At around 1:00 while Connie was filling the spectrograph dewars, she noticed a low frequency hum and vibration from the rotator. The rotator oscillation ( ~20 Hz ) was noted at mount angles ranging between 120 and 205 degrees at elevations between 57 and 86 degrees. The oscillation was large enough to make image quality poor. It was worrying enough with spectro and imager optics mounted that we decided not to do any more tracking. We again set up on the meridian and equator and parked. I attempted to run the tpm tonight, but got the following when I tried. TPM>start data TPM>[TPM,tShell,3,E] Looking for v3 format, found v1. Need to recompile. stop ERROR: Data is not currently being logged. TPM> Out of focus images showed some coma, so we decided to adjust the primary. We first homed the secondary to assure a proper starting point. Excerpts of the home are below, and seem to show rather large errors. :XQ#HOME : 0000.0, 0000.0, 0000.0, 0000.0, 0000.0 sec to set up motion 0400.2, 0400.2, 0400.2, 0006.5, 0006.5 max sec to find reverse limit switch 0030.1, 0030.1, 0030.1, 0030.1, 0030.1 max sec to find home switch 0010.2, 0010.2, 0010.2, 0000.5, 0000.5 sec to move away from home switch 0002.3, 0002.3, 0002.3, 0000.1, 0000.1 max sec to find index 036, 002.1 microsteps, sec to find full step -000040000, -000030000, 000000000, 000001050, 000000350 position error 1, 1, 1, 1, 1 axis homed There was also a rogue COLLIMATE process which did not die when STOP COLLIMATE was issued. A SHOW SYSTEM revealed it and its PID, and it was stopped. The telescope was taken to 87 deg once the collimate process was dead and the primary was set using setmir to all zeros ( the nominal mechanical collimation position ). It was then relaxed and taken back down to the equator. The secondary was placed in the proper position for 57.22 deg altitude 1577.3, -180.0, -160.0, 0.0,110.9 We then applied tilts to eliminate coma. The numbers which did this were 0, -2, 30, 0, 0 Next we used equations to back out the proper tilt and translation values from the tilt only values. The equations were from Pat Waddell in a message at the end of February excerpted here Assuming that M1 is "mechanically" collimated Using SETMIR, find tx0 and ty0 (arcseconds) to remove coma This implies that the M1 center is displaced (in microns) from the rotator axis and may be found at cx = ty0 * 42.7 cy = -tx0 * 42.7 Thus M1 must be moved to position dx = -cx, dy = -cy, or dx = -ty0 * 42.7 dy = tx0 * 42.7 And to keep proper axis alignment M1 must be tilted (from the original attitude) tx = -dy * 0.0183 ty = dx * 0.0183 final SETMIR command: 0 (piston), tx, ty, dx, dy This gave the final setmir command 0, 1.6, -23.4, -1281, -85 These were implemented, and the primary relaxed at 87 deg. When we slewed back to the equator, it was obvious that these numbers were not right. The images were quite comatic. I hope someone can figure out what was wrong and take the tilt-only values we found which eliminated coma and generate the correct tilt and translation values. The telescope was put away at 05:20. Dan